SHOWTEC 51336 Скачать руководство пользователя страница 7

 

Proper Usage Safety and Compliance Information 

 

 
 
 

According to FDA Regulations you 
should operate this product as stated on 
the left. 

 
 
 
 
 
 
 
 
 

Operating Determinations 

 

This device is not designed for permanent operation. Consistent operation breaks will ensure that the 
device will serve you for a long time without defects. 

 

The minimum distance between light-output and the illuminated surface must be more than 0.5 meter. 

 

The maximum ambient temperature 

t

a

 = 45°C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 35° C. 

 

If this device is operated in any other way, than the one described in this manual, the product may 
suffer damages and the

 

warranty becomes void. 

 

Any other operation may lead to dangers like short-circuit, burns, electric shock, crash, etc. 

 
 

You endanger your own safety and the safety of others!

 

 

 

Rigging

 

Please follow the European and national guidelines concerning rigging, trussing and all other 
safety issues. 

 

Do not attempt the installation yourself ! 
Always let the installation be carried out by an authorized dealer !

 

 

Procedure: 

 

If the Galactic GBC-120 is lowered from the ceiling or high joists, professional trussing systems have 
to be used. 

 

Use a clamp to mount the Galactic GBC-120, with the mounting-bracket, to the trussing system. 

 

The Galactic GBC-120 must never be fixed swinging freely in the room.  

 

The installation must always be secured with a safety attachment, e.g. an appropriate safety net 
or safety-cable. 

 

When rigging, derigging or servicing the device, always make sure, that the area below the 
installation place is blocked and staying in the area is forbidden. 

 

Improper installation can cause serious damage to people and property !

 

 

 

Содержание 51336

Страница 1: ...Galactic GBC 120 ORDERCODE 51336 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...gn and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant show...

Страница 3: ...1 One Galactic RGY 140 Sound control 11 Multiple Galactics Master Slave control 11 Multiple Galactic RGY 140 DMX Control 12 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addr...

Страница 4: ...n and maintenance of this device have to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there...

Страница 5: ...o extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the powe...

Страница 6: ...ntification Laser Classification Class IIIB Cooling TE Cooling Laser medium wavelength 532 nm Green DPSS Medium DPSS Nd YVO4 40mW wavelength 450 nm Blue DPSS Medium LD GeAs 80mW Output 120mW Beam Diam...

Страница 7: ...hort circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other s...

Страница 8: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 9: ...es Laser Class IIIB Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Color Green Blue Cyan Laser Power 120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto S...

Страница 10: ...11 12 1 Mountingbracket with adjustment screw 7 Earth connection 2 3 pin DMX Out 8 Remote Control 3 ON OFF 9 Lock On Off 4 Fuse 1A 250V 10 Safety Eye 5 IEC Powerconnector 11 LCD Display Menu Buttons 6...

Страница 11: ...hen sound signal is detected During a sound controlled Show press MUSIC B 1 9 to set the sensitivity 9 is the most sensitive COLOR CHANGE Cycle through the pre programmed colors PATTERN CHANGE To show...

Страница 12: ...d safety keys are included in the box The interlock is the included in the box successor for the optional remote interlock 51316 They should be kept with the Galactic GBC 120 laser The following safet...

Страница 13: ...t of the music Please see page 16 for more information about the sound control options Multiple Galactics Master Slave control 1 Fasten the effect light onto firm trussing Leave at least 1 meter on al...

Страница 14: ...erating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link mus...

Страница 15: ...ic GBC 120 should be 1 10 11 the DMX address of the third Galactic GBC 120 should be 11 10 21 etc Please be sure that you don t have any overlapping channels in order to control each Galactic GBC 120...

Страница 16: ...14 Menu Overview The Galactic GBC 120 will only show its version number at start up...

Страница 17: ...s from 3 Use the ENTER button to store your setting 2 Slave Mode With this menu you are able to set the device as a slave device 1 Press the FUNC button until the display shows 2 Use the ENTER button...

Страница 18: ...o select 4 Use the ENTER button to store your setting 6 Sensitivity Mode With this menu you can set the Audio Sensitivity 1 Press the FUNC button until the display shows 2 You can choose 10 different...

Страница 19: ...175 199 Blue Cyan 200 224 Blue Green Cyan 225 255 Color flow Channel 4 Color Changing Speed when CH3 is set between 125 255 0 4 Stop 5 255 Color changing speed from slow to fast Channel 5 Zoom 0 127...

Страница 20: ...0 359 degree fixed X Axis rolling 128 191 Counterclockwise rotation from slow to fast 192 255 Clockwise rotation from slow to fast Patterns 000 007 064 071 128 135 192 199 008 015 072 079 136 143 200...

Страница 21: ...own or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product sp...

Страница 22: ...efective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination...

Страница 23: ...120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto Sound Master Slave DMX 3 pin DMX In and 3 pin DMX Out Clear LCD display for all settings Compact stro...

Страница 24: ......

Отзывы: