background image

10 

 

Installation

 

Remove all packing materials from the Galactic GBC-120. Check that all foam and plastic padding is 
removed. Connect all cables. 

Always disconnect from electric mains power supply before cleaning or servicing. 
Damages caused by non-observance are not subject to warranty.

 

 
 

Set Up and Operation

 

Before plugging the unit in, always make sure that the power supply matches the product specification 
voltage. Do not attempt to operate a 120V specification product on 230V power, or vice versa.

 

Connect the device to the main power supply. The device can be music-controlled by its built-in 
microphone.  

 

The Interlock plug/remote plug and safety keys are included in the box. 
The interlock is the “included-in-the-box” successor for the optional remote interlock (51316) 

 

         They should be kept with the Galactic GBC-120 laser !!! 

 

The following safety precautions should be followed: 
-The interlock plug should be placed on the backside (

8

) of your Galactic GBC-120 laser.  

-The keys should be put into the lock (

9

) of your Galactic GBC-120 laser. 

 

 

       Warning

  

If the plug is not connected, your laser will not function. 
If the key is not set to ON, your laser will not function. 

 

 

 

 

Exclusion of liability 

Be aware that in some countries, there are additional regulations, regarding the use of laser devices. 
Therefore, we strongly advise you to check your national laws with the authorities: We don’t take any 
responsibility for eventual discrepancies, changes or adaptions regarding lawful use of laser devices.

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

 
 

 

Содержание 51336

Страница 1: ...Galactic GBC 120 ORDERCODE 51336 Highlite International B V Vestastraat 2 6468 EX Kerkrade The Netherlands Phone 31 45 5667700...

Страница 2: ...gn and manufacture professional light equipment for the entertainment industry New products are being launched regularly We work hard to keep you our customer satisfied For more information iwant show...

Страница 3: ...1 One Galactic RGY 140 Sound control 11 Multiple Galactics Master Slave control 11 Multiple Galactic RGY 140 DMX Control 12 Fixture Linking 12 Data Cabling 12 Control Panel 13 Control Mode 13 DMX Addr...

Страница 4: ...n and maintenance of this device have to be qualified follow the instructions of this manual Before your initial start up please make sure that there is no damage caused by transportation Should there...

Страница 5: ...o extreme heat moisture or dust Make sure that the available voltage is not higher than stated on the rear panel Make sure that the power cord is never crimped or damaged Check the device and the powe...

Страница 6: ...ntification Laser Classification Class IIIB Cooling TE Cooling Laser medium wavelength 532 nm Green DPSS Medium DPSS Nd YVO4 40mW wavelength 450 nm Blue DPSS Medium LD GeAs 80mW Output 120mW Beam Diam...

Страница 7: ...hort circuit burns electric shock crash etc You endanger your own safety and the safety of others Rigging Please follow the European and national guidelines concerning rigging trussing and all other s...

Страница 8: ...od to use Note If you are given an RMA number please include the following information on a piece of paper inside the box 1 Your name 2 Your address 3 Your phone number 4 A brief description of the sy...

Страница 9: ...es Laser Class IIIB Laser Safety EN IEC 60825 1 Ed 2 2007 03 Laser Color Green Blue Cyan Laser Power 120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto S...

Страница 10: ...11 12 1 Mountingbracket with adjustment screw 7 Earth connection 2 3 pin DMX Out 8 Remote Control 3 ON OFF 9 Lock On Off 4 Fuse 1A 250V 10 Safety Eye 5 IEC Powerconnector 11 LCD Display Menu Buttons 6...

Страница 11: ...hen sound signal is detected During a sound controlled Show press MUSIC B 1 9 to set the sensitivity 9 is the most sensitive COLOR CHANGE Cycle through the pre programmed colors PATTERN CHANGE To show...

Страница 12: ...d safety keys are included in the box The interlock is the included in the box successor for the optional remote interlock 51316 They should be kept with the Galactic GBC 120 laser The following safet...

Страница 13: ...t of the music Please see page 16 for more information about the sound control options Multiple Galactics Master Slave control 1 Fasten the effect light onto firm trussing Leave at least 1 meter on al...

Страница 14: ...erating mode The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support Important Fixtures on a serial data link mus...

Страница 15: ...ic GBC 120 should be 1 10 11 the DMX address of the third Galactic GBC 120 should be 11 10 21 etc Please be sure that you don t have any overlapping channels in order to control each Galactic GBC 120...

Страница 16: ...14 Menu Overview The Galactic GBC 120 will only show its version number at start up...

Страница 17: ...s from 3 Use the ENTER button to store your setting 2 Slave Mode With this menu you are able to set the device as a slave device 1 Press the FUNC button until the display shows 2 Use the ENTER button...

Страница 18: ...o select 4 Use the ENTER button to store your setting 6 Sensitivity Mode With this menu you can set the Audio Sensitivity 1 Press the FUNC button until the display shows 2 You can choose 10 different...

Страница 19: ...175 199 Blue Cyan 200 224 Blue Green Cyan 225 255 Color flow Channel 4 Color Changing Speed when CH3 is set between 125 255 0 4 Stop 5 255 Color changing speed from slow to fast Channel 5 Zoom 0 127...

Страница 20: ...0 359 degree fixed X Axis rolling 128 191 Counterclockwise rotation from slow to fast 192 255 Clockwise rotation from slow to fast Patterns 000 007 064 071 128 135 192 199 008 015 072 079 136 143 200...

Страница 21: ...own or unclear it is burned out 4 Insert the replacement fuse into the holder where the old fuse was Reinsert the fuse cover Be sure to use a fuse of the same type and specification See the product sp...

Страница 22: ...efective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cables Data link not terminated with 120 Ohm termination...

Страница 23: ...120mW 40mW 532nm Green 80mW 450nm Blue Scan Angle 30 Scan Speed Stepping motor Control Modes Auto Sound Master Slave DMX 3 pin DMX In and 3 pin DMX Out Clear LCD display for all settings Compact stro...

Страница 24: ......

Отзывы: