SHOWTEC 50804 Скачать руководство пользователя страница 6

 

  

 

 

   

 

Ordercode: 50804 

Net-8/3 

 

 

Return Procedure 

 

Returned merchandise must be sent prepaid and in the original packing, call tags will not be issued. 
Package must be clearly labeled with a Return Authorization Number (RMA number). Products returned 
without an RMA number will be refused. Highlite will not accept the returned goods or any responsibility. 
Call Highlite 0031-455667723 or mail 

[email protected]

 and request an RMA prior to shipping the fixture. 

Be prepared to provide the model number, serial number and a brief description of the cause for the 
return. Be sure to properly pack fixture, any shipping damage resulting from inadequate packaging is the 
customer’s responsibility. Highlite reserves the right to use its own discretion to repair or replace 
product(s). As a suggestion, proper UPS packing or double-boxing is always a safe method to use. 
 

Note: If you are given an RMA number, please include the following information on a piece of paper 
inside the box: 

01)

 

Your name 

02)

 

Your address 

03)

 

Your phone number 

04)

 

A brief description of the symptoms 

 

Claims 

The client has the obligation to check the delivered goods immediately upon delivery for any short-
comings and/or visible defects, or perform this check after our announcement that the goods are at their 
disposal. Damage incurred in shipping is the responsibility of the shipper; therefore the damage must be 
reported to the carrier upon receipt of merchandise. 
It is the customer's responsibility to notify and submit claims with the shipper in the event that a fixture is 
damaged due to shipping. Transportation damage has to be reported to us within one day after receipt 
of the delivery. 
Any return shipment has to be made post-paid at all times. Return shipments must be accompanied with 
a letter defining the reason for return shipment. Non-prepaid return shipments will be refused, unless 
otherwise agreed in writing. 
Complaints against us must be made known in writing or by fax within 10 working days after receipt of the 
invoice. After this period complaints will not be handled anymore. 
Complaints will only then be considered if the client has so far complied with all parts of the agreement, 
regardless of the agreement of which the obligation is resulting. 

 

 

Содержание 50804

Страница 1: ...Net 8 3 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50804 MANUAL ENGLISH...

Страница 2: ...3 with Laptop PC 8 Setup Net 8 3 with Lighting controller 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Status Menu 11 Main Menu Options 12 1 Rename 12 2 Set DHCP 12 3 Set IP Address 12 4 Set...

Страница 3: ...ment includes Showtec Net 8 3 Schuko to Pro Power connector power cable 1 3m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to...

Страница 4: ...Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage...

Страница 5: ...her operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others The Net 8 3 can be mounted in a 19 inch mounting rack Improper...

Страница 6: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 7: ...front Supports both Artnet or Klingnet protocol 1 Gbps data speed 8 universes DMX input or output High speed network in and output Input voltage 100 240VAC 50 60 Hz Power consumption 20W max Fuse F1A...

Страница 8: ...ll foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleanin...

Страница 9: ...h the Net 8 3 cat 5 6 etc cable 04 Connect the Laptop PC with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket D...

Страница 10: ...3 cat 5 6 etc cable 04 Connect the lighting controller with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket Do...

Страница 11: ...You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a hig...

Страница 12: ...s status mode shows the device name which can be changed in the main menu For more information see 1 Rename on page 12 With this mode you are able to see which port is connected not connected X or dis...

Страница 13: ...LEFT button to go back to the previous step 07 After editing the name press the UP DOWN buttons to select Cancel to exit without saving or Enter to save the setting 08 Press the RIGHT button to confir...

Страница 14: ...gh the three options A B or C 04 The selected option will be highlighted 05 Press the RIGHT button to confirm the desired option 5 Set DMX Port 01 Press the LEFT button to enter the main menu 02 In th...

Страница 15: ...he inputs and sends the last changed value to the DMX port for each DMX channel in both universes Note DMX Merging is when two or more sources of DMX are combined into one control stream in order to c...

Страница 16: ...tons to select LCD Backlight and press the RIGHT button to open the submenu The display shows 03 Press the UP DOWN buttons to choose ON or OFF 04 The selected option will be highlighted 05 If you choo...

Страница 17: ...r ArtNet receiver Isolated mode The node receives 8 separate ArtNet unverses and sends them to the 8 DMX output ports A network configuration needs to be done according to your network and your ArtNet...

Страница 18: ...the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the repl...

Страница 19: ...ity or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cabl...

Страница 20: ...male RJ45 Signal output 3 pin XLR female RJ45 Power connection Pro Power connector Control protocol ArtNET KlingNET sACN TCP IPv4 DMX 512 Electro mechanical effects 8 universes DMX input or output Dat...

Страница 21: ...20 Ordercode 50804 Net 8 3 Dimensions...

Страница 22: ...21 Ordercode 50804 Net 8 3 Notes...

Страница 23: ...22 Ordercode 50804 Net 8 3...

Страница 24: ...2016 Showtec...

Отзывы: