SHOWTEC 50804 Скачать руководство пользователя страница 4

 

  

 

 

   

 

Ordercode: 50804 

Net-8/3 

IMPORTANT: 

The manufacturer will not accept liability for any resulting damages caused by the non-observance of 
this manual or any unauthorized modification to the device. 
 

 

Never let the power cord come into contact with other cables! Handle the power cord and all 
connections with the mains with particular caution! 

 

Never remove warning or informative labels from the unit. 

 

Never use anything to cover the ground contact. 

 

Never leave any cables lying around. 

 

Do not connect this device to a dimmerpack. 

 

Do not switch the device on and off in short intervals, as this would reduce the device’s life. 

 

Do not touch the device’s housing bare-handed during its operation. Allow the fixture to cool for at 
least 5 minutes before handling. 

 

Do not shake the device. Avoid brute force when installing or operating the device. 

 

Only use device indoor, avoid contact with water or other liquids. 

 

Only operate the fixture after having checked that the housing is firmly closed and all screws are 
tightly fastened. 

 

Only operate the device after having familiarized with its functions. 

 

Avoid flames and do not put close to flammable liquids or gases. 

 

Always keep case closed while operating. 

 

Always allow free air space of at least 50 cm around the unit for ventilation. 

 

Always disconnect power from the mains, when device is not used or before cleaning! Only handle 
the power cord by the plug. Never pull out the plug by tugging the power cord. 

 

Make sure that the device is not exposed to extreme heat, moisture or dust. 

 

Make sure that the available voltage is not higher than stated on the rear panel. 

 

Make sure that the power cord is never crimped or damaged. Check the device and the power 
cord from time to time. 

 

If device is dropped or struck, disconnect mains power supply immediately. Have a qualified 
engineer inspect for safety before operating. 

 

If the device has been exposed to drastic temperature fluctuation (e.g. after transportation), do not 
switch it on immediately. The arising condensation water might damage your device. Leave the 
device switched off until it has reached room temperature. 

 

If your Showtec device fails to work properly, discontinue use immediately. Pack the unit securely 
(preferably in the original packing material), and return it to your Showtec dealer for service. 

 

For adult use only. Device must be installed out of the reach of children. Never leave the unit running 
unattended. 

 

Never attempt to bypass the thermostatic switch or fuses. 

 

The user is responsible for correct positioning and operating of the Net-8/3. The manufacturer will not 
accept liability for damages caused by the misuse or incorrect installation of this device. 

 

This device falls under protection class I. Therefore it is essential to connect the yellow/green 
conductor to earth. 

 

Repairs, servicing and electric connection must be carried out by a qualified technician. 

 

WARRANTY: Till one year after date of purchase. 

 

 

Содержание 50804

Страница 1: ...Net 8 3 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50804 MANUAL ENGLISH...

Страница 2: ...3 with Laptop PC 8 Setup Net 8 3 with Lighting controller 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Status Menu 11 Main Menu Options 12 1 Rename 12 2 Set DHCP 12 3 Set IP Address 12 4 Set...

Страница 3: ...ment includes Showtec Net 8 3 Schuko to Pro Power connector power cable 1 3m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to...

Страница 4: ...Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage...

Страница 5: ...her operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others The Net 8 3 can be mounted in a 19 inch mounting rack Improper...

Страница 6: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 7: ...front Supports both Artnet or Klingnet protocol 1 Gbps data speed 8 universes DMX input or output High speed network in and output Input voltage 100 240VAC 50 60 Hz Power consumption 20W max Fuse F1A...

Страница 8: ...ll foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleanin...

Страница 9: ...h the Net 8 3 cat 5 6 etc cable 04 Connect the Laptop PC with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket D...

Страница 10: ...3 cat 5 6 etc cable 04 Connect the lighting controller with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket Do...

Страница 11: ...You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a hig...

Страница 12: ...s status mode shows the device name which can be changed in the main menu For more information see 1 Rename on page 12 With this mode you are able to see which port is connected not connected X or dis...

Страница 13: ...LEFT button to go back to the previous step 07 After editing the name press the UP DOWN buttons to select Cancel to exit without saving or Enter to save the setting 08 Press the RIGHT button to confir...

Страница 14: ...gh the three options A B or C 04 The selected option will be highlighted 05 Press the RIGHT button to confirm the desired option 5 Set DMX Port 01 Press the LEFT button to enter the main menu 02 In th...

Страница 15: ...he inputs and sends the last changed value to the DMX port for each DMX channel in both universes Note DMX Merging is when two or more sources of DMX are combined into one control stream in order to c...

Страница 16: ...tons to select LCD Backlight and press the RIGHT button to open the submenu The display shows 03 Press the UP DOWN buttons to choose ON or OFF 04 The selected option will be highlighted 05 If you choo...

Страница 17: ...r ArtNet receiver Isolated mode The node receives 8 separate ArtNet unverses and sends them to the 8 DMX output ports A network configuration needs to be done according to your network and your ArtNet...

Страница 18: ...the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the repl...

Страница 19: ...ity or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cabl...

Страница 20: ...male RJ45 Signal output 3 pin XLR female RJ45 Power connection Pro Power connector Control protocol ArtNET KlingNET sACN TCP IPv4 DMX 512 Electro mechanical effects 8 universes DMX input or output Dat...

Страница 21: ...20 Ordercode 50804 Net 8 3 Dimensions...

Страница 22: ...21 Ordercode 50804 Net 8 3 Notes...

Страница 23: ...22 Ordercode 50804 Net 8 3...

Страница 24: ...2016 Showtec...

Отзывы: