Maintenance 

The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by an expert after every year in the course of an acceptance test.  
The operator has to make sure that safety-related and machine-technical installations are to be 
inspected by a skilled person once a year. 
 
The following points have to be considered during the inspection:  
01)

 

All screws used for installing the device or parts of the device have to be tightly connected and must 
not be corroded. 

02)

 

There may not be any deformations on housings, fixations and installation spots. 

03)

 

Mechanically moving parts like axles, eyes and others may not show any traces of wearing. 

04)

 

The electric power supply cables must not show any damages or material fatigue. 

 
The Showtec Net-8/3 requires almost no maintenance. However, you should keep the unit clean. 
Disconnect the mains power supply and then wipe the cover with a damp cloth. Wipe the front glass 
panel clean with glass cleaner and a soft cloth. Do not use alcohol or solvents. Do not immerse in liquid.  
Keep connections clean. Disconnect electric power, and then wipe the DMX and audio connections 
with a damp cloth. Make sure connections are thoroughly dry before linking equipment or supplying 
electric power. 
 

Replacing the Fuse 

Power surges, short-circuit or inappropriate electrical power supply may cause a fuse to burn out. If the 
fuse burns out, the product will not function whatsoever. If this happens, 

follow the directions below to do 

so.

 

01)

 

Unplug the unit from electric power source

02)

 

Insert a flat-headed screwdriver into a slot in the fuse cover. Turn the screwdriver to the left, at the 
same time gently push a bit (Turn and Push). The fuse will come out. 

03)

 

Remove the used fuse. If brown or unclear, it is burned out

04)

 

Insert the replacement fuse into the holder where the old fuse was. Reinsert the fuse holder. Be sure 
to 

use a fuse of the same type and specification. See the product specification label for details. 

 

Troubleshooting 

 

No Light 

This troubleshooting guide is meant to help solve simple problems.  
If a problem occurs, carry out the steps below in sequence until a solution is found. Once the unit 
operates properly, do not carry out following steps. 
If the light effect does not operate properly, refer servicing to a technician. 
Suspect three potential problem areas as: the power supply, the distributor or the fuse. 
01)

 

Power supply. Check if the unit is plugged into an appropriate power supply. 

02)

 

The distributor. Return the Net-8/3 to your Showtec dealer. 

03)

 

The fuse. Replace the fuse. See page 17 for replacing the fuse. 

04)

 

If all of the above appears to be O.K., plug the unit in again. 

05)

 

If you are unable to determine the cause of the problem, do not open the Net-8/3, as this may 
damage the unit and the warranty will become void. 

06)

 

Return the device to your Showtec dealer. 

 

No Response to DMX 

Response: Suspect the DMX cable or connectors, a controller malfunction, a light effect DMX card 
malfunction. 
01)

 

Check the DMX setting. Make sure that DMX addresses are correct. 

02)

 

Check the DMX cable: Unplug the unit; change the DMX cable; then reconnect to electrical power. 
Try your DMX control again. 

03)

 

Determine whether the DMX recorder, light controller or light effect is at fault. Does the controller 
operate properly with other DMX products ? If not, take the controller in for repair. If so, take the DMX 
cable and/or the light effect to a qualified technician. 

 

Содержание 50804

Страница 1: ...Net 8 3 V1 Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Ordercode 50804 MANUAL ENGLISH...

Страница 2: ...3 with Laptop PC 8 Setup Net 8 3 with Lighting controller 9 Fixture Linking 10 Data Cabling 10 Control Panel 11 Status Menu 11 Main Menu Options 12 1 Rename 12 2 Set DHCP 12 3 Set IP Address 12 4 Set...

Страница 3: ...ment includes Showtec Net 8 3 Schuko to Pro Power connector power cable 1 3m User manual Safety Instructions Every person involved with the installation operation and maintenance of this device has to...

Страница 4: ...Only handle the power cord by the plug Never pull out the plug by tugging the power cord Make sure that the device is not exposed to extreme heat moisture or dust Make sure that the available voltage...

Страница 5: ...her operation may lead to dangers like short circuit burns electric shock crash etc You endanger your own safety and the safety of others The Net 8 3 can be mounted in a 19 inch mounting rack Improper...

Страница 6: ...er 04 A brief description of the symptoms Claims The client has the obligation to check the delivered goods immediately upon delivery for any short comings and or visible defects or perform this check...

Страница 7: ...front Supports both Artnet or Klingnet protocol 1 Gbps data speed 8 universes DMX input or output High speed network in and output Input voltage 100 240VAC 50 60 Hz Power consumption 20W max Fuse F1A...

Страница 8: ...ll foam and plastic padding is removed Connect all cables Do not supply power before the whole system is set up and connected properly Always disconnect from electric mains power supply before cleanin...

Страница 9: ...h the Net 8 3 cat 5 6 etc cable 04 Connect the Laptop PC with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket D...

Страница 10: ...3 cat 5 6 etc cable 04 Connect the lighting controller with the network switch cat 5 6 etc cable 05 Supply electric power Plug the units mains power cord into a proper electric power supply socket Do...

Страница 11: ...You can purchase DAP Audio certified DMX cables directly from a dealer distributor or construct your own cable If you choose to create your own cable please use data grade cables that can carry a hig...

Страница 12: ...s status mode shows the device name which can be changed in the main menu For more information see 1 Rename on page 12 With this mode you are able to see which port is connected not connected X or dis...

Страница 13: ...LEFT button to go back to the previous step 07 After editing the name press the UP DOWN buttons to select Cancel to exit without saving or Enter to save the setting 08 Press the RIGHT button to confir...

Страница 14: ...gh the three options A B or C 04 The selected option will be highlighted 05 Press the RIGHT button to confirm the desired option 5 Set DMX Port 01 Press the LEFT button to enter the main menu 02 In th...

Страница 15: ...he inputs and sends the last changed value to the DMX port for each DMX channel in both universes Note DMX Merging is when two or more sources of DMX are combined into one control stream in order to c...

Страница 16: ...tons to select LCD Backlight and press the RIGHT button to open the submenu The display shows 03 Press the UP DOWN buttons to choose ON or OFF 04 The selected option will be highlighted 05 If you choo...

Страница 17: ...r ArtNet receiver Isolated mode The node receives 8 separate ArtNet unverses and sends them to the 8 DMX output ports A network configuration needs to be done according to your network and your ArtNet...

Страница 18: ...the fuse cover Turn the screwdriver to the left at the same time gently push a bit Turn and Push The fuse will come out 03 Remove the used fuse If brown or unclear it is burned out 04 Insert the repl...

Страница 19: ...ity or broken cables missing termination plug or a defective fixture disturbing the link Bad data link connection Inspect connections and cables Correct poor connections Repair or replace damaged cabl...

Страница 20: ...male RJ45 Signal output 3 pin XLR female RJ45 Power connection Pro Power connector Control protocol ArtNET KlingNET sACN TCP IPv4 DMX 512 Electro mechanical effects 8 universes DMX input or output Dat...

Страница 21: ...20 Ordercode 50804 Net 8 3 Dimensions...

Страница 22: ...21 Ordercode 50804 Net 8 3 Notes...

Страница 23: ...22 Ordercode 50804 Net 8 3...

Страница 24: ...2016 Showtec...

Отзывы: