4
(2) Optical system:
RGB mix beam be reflected out by X,Y scan mirrors.
6. Scan motor Replacement
(1) Steps:
1. Unscrew UK M6 screw and plug out male signal connector.
2. Disassemble all M4
10 screw for X,Y scanner socket so that scan motors can
be took out,put in or rotate to adjust the scan angle.
3. After adjust ,fix M4
screws,plug in male signal connector and then screw
UK M6 screw.
10
Y scan motor
X scan motor
UK M6 screw (with femal screw)
Signal connector(Male)
M4
10 screw
M4
10 screw
Fig6-1 Scan motor install diagram
White beam
RGB mix beam
Fig6-2 Optical System diagram