9
Water warning:
• Do not expose the device to rain, use it near water or in damp or wet conditions on it containing liquids which might spill
into any openings. Never insert or remove an electric plug with wet hands.
If you notice any abnormality:
• If the power cord or plug becomes frayed or damaged, or if there is a sudden loss of sound during use of the device, or if
any unusual smells or smoke should appear to be caused by it, immediately turn off the power switch, disconnect the
electric plug from the outlet, and have the device inspected by qualified service personnel.
INSTALLATION
The Showlite PAR64 8Wx18 LED-lighting effect is designed as floor effect or for overhead
rigging on stages, in discotheques, theatres, etc. During installation consider all necessary
safety instructions especially
EN 60598-2-17
and national standards. Please note: for
overhead rigging in public or industrial areas, a series of safety instructions have to be
considered. This manual can only give a survey and does not list complete instructions.
Installation must only be done by authorized and experienced operators.
Overhead rigging
Important! Overhead rigging must only be done by authorized and experienced
operators. Always install an appropriate safety bond.
You must only use safety bonds and quick links complying with DIN 56927, shakles
complying with DIN EN 1677-1 and BGV C1 carbines.All devices must be sufficiently
dimensioned and used correctly in accordance to the latest industrial safety regulations.
The installation of the device hast o be built and constructed in a way that it can hold 10
times the weight for 1 hour without any harming deformation. The maximum drop distance
must never exceed 20 cm. A safety bond which already held the strain of a crash or which is
defective must not be used again.
Power connection and DMX
After save installation (floor or overhead) please connect the power cable to 220(230)V
50(60) Hz power voltage. You can operate the lighting device by an external DMX controller
or by internal preset programs. If using a DMX controller connect the controller DMX-OUT
with the lighting DMX-IN. To connect several lighting effects set up a DMX loop by
connecting DMX-OUT of first device with DMX-IN of second divice and so on.
DMX-connectors and backside operator panel:
E
N
G
L
I
S
H
2
Bedienungsanleitung
Inhaltsverzeichnis
Vorsichtsmaßnahmen
3
Montage und Inbetriebnahme
4
Netzanschluss und DMX
5
Rückseitige Anschlüsse und Bedienelemente
5
Bedienung und Parametrierung
5
DMX512 Kanäle / WEEE Erklärung
10
Technical Data:
Artikelnummern
00034574 (RGBW) / 00034575 (RGBA)
Farbmischung
RGBW/RGBA Farbmischung
Spannungsversorgung
230V - 50/60Hz
Leistungsaufnahme
175 Watt
Betriebstemperatur
-20° … 40°
Abstrahlwinkel
25°
Anschlüsse
DMX in/out (XLR)
DMX Kanäle
8 DMX
Abmessungen (d x L)
250mm x 300mm
Gewicht
ca. 2.9 kg
D
E
U
T
S
C
H