Water warning: 

 
• Do not expose the device to rain, use it near water or in damp or wet conditions on it containing liquids which might spill 
into any openings. Never insert or remove an electric plug with wet hands. 
 

If you notice any abnormality: 

 
• If the power cord or plug becomes frayed or damaged, or if there is a sudden loss of sound during use of the device, or if 
any unusual smells or smoke should appear to be caused by it, immediately turn off the power switch, disconnect the 
electric plug from the outlet, and have the device inspected by qualified service personnel. 
 
 
 
 

INSTALLATION 

 

The Showlite PAR64 8Wx18 LED-lighting effect is designed as floor effect or for overhead 
rigging on stages, in discotheques, theatres, etc. During installation consider all necessary 

safety  instructions  especially 

EN  60598-2-17

  and  national  standards.  Please  note:  for 

overhead  rigging  in  public  or  industrial  areas,  a  series  of  safety  instructions  have  to  be 
considered. This manual can only give a survey and does not list complete instructions.  
Installation must only be done by authorized and experienced operators. 

 

Overhead rigging

 

 

Important!  Overhead  rigging  must  only  be  done  by  authorized  and  experienced 
operators. Always install an appropriate safety bond.  

 
You  must  only  use  safety  bonds  and  quick  links  complying  with  DIN  56927,  shakles 
complying  with  DIN  EN  1677-1  and  BGV  C1  carbines.All  devices  must  be  sufficiently 
dimensioned and used correctly in accordance to the latest industrial safety regulations. 
The installation of the device hast o be built and constructed in a way that it can hold 10 
times the weight for 1 hour without any harming deformation. The maximum drop distance 
must never exceed 20 cm. A safety bond which already held the strain of a crash or which is 
defective must not be used again. 

 

Power connection and DMX 

 
After  save  installation  (floor  or  overhead)  please  connect  the  power  cable  to  220(230)V 
50(60) Hz power voltage. You can operate the lighting device by an external DMX controller 
or by internal preset programs. If using a DMX controller connect the controller DMX-OUT 
with  the  lighting  DMX-IN.  To  connect  several  lighting  effects  set  up  a  DMX  loop  by 
connecting DMX-OUT of first device with DMX-IN of second divice and so on. 
 

DMX-connectors and backside operator panel: 

 
 

 
 
 
 
 
 
 



 

Bedienungsanleitung

 

 
 
Inhaltsverzeichnis 

 
 
Vorsichtsmaßnahmen 

 

 

 

 

    3 

 
Montage und Inbetriebnahme 

 

 

 

    4 

 
Netzanschluss und DMX   

 

 

 

    5 

 
Rückseitige Anschlüsse und Bedienelemente   

    5 

 
Bedienung und Parametrierung       

 

 

    5 

 
DMX512 Kanäle / WEEE Erklärung 

 

 

  10 

 
 

Technical Data: 

 

Artikelnummern 

00034574 (RGBW) / 00034575 (RGBA) 

Farbmischung 

RGBW/RGBA Farbmischung 

Spannungsversorgung 

230V -  50/60Hz 

Leistungsaufnahme 

175 Watt 

  Betriebstemperatur 

-20° … 40° 

Abstrahlwinkel 

25° 

  Anschlüsse 

DMX in/out (XLR) 

DMX Kanäle 

8 DMX 

Abmessungen (d x L) 

250mm x 300mm

 

Gewicht 

ca. 2.9 kg 

 

D
E
U
T
S
C

Содержание PAR 64 18x8W RGBA XT

Страница 1: ...ikhaus Kirstein GmbH in irgendeiner Weise sei es ausdrücklich oder durch schlüssiges Handeln rechtlich zu binden Diese Bedienungsanleitung ist urheberrechtlich geschützt Jede Vervielfältigung bzw jeder Nachdruck auch auszugsweise und jede Wiedergabe der Abbildungen auch in verändertem Zustand ist nur mit schriftlicher Zustimmung der Firma Musikhaus Kirstein GmbH gestattet Your product is designed ...

Страница 2: ...4 8Wx18 LED RGBW A Please read through this manual carefully before beginning to use so that you will be able to take full advantage of the Showlite PAR64 8Wx18 LED RGBW A features and enjoy trouble free operation for years to come Please keep this manual at a safe and dry place where you easily can access it Caution Before switching on the instrument or device read carefully the safety instructio...

Страница 3: ... shakles complying with DIN EN 1677 1 and BGV C1 carbines All devices must be sufficiently dimensioned and used correctly in accordance to the latest industrial safety regulations The installation of the device hast o be built and constructed in a way that it can hold 10 times the weight for 1 hour without any harming deformation The maximum drop distance must never exceed 20 cm A safety bond whic...

Страница 4: ...erious injury or even death from electrical shock short circuiting damages fire or other hazards These precautions include but are not limited to the following Power supply power cord devices with power cords power supplies Only use the voltage specified as correct for the device The required voltage is printed on the type plate of the device Check the power cable from time to time regarding dirt ...

Страница 5: ...formierung das 10 fache der Nutzlast aushalten kann Die Installation muss immer mit einer zweiten unabhängigen Aufhängung z B einem geeigneten Fangnetz oder Fangseil erfolgen Diese zweite Aufhängung muss so beschaffen und angebracht sein dass im Fehlerfall der Hauptaufhängung kein Teil der Installation herabfallen kann Der maximale Fallabstand darf 20 cm nicht überschreiten Ein Sicherungsseil das ...

Страница 6: ...bt über DMX die Steuerbefehle an Slave Scheinwerfer weiter Diese folgen der Masterfunktion Auto Programme Hier können sie mehrere Einzelprogramme zu einer Ablaufsequenz zusammenstellen Der Scheinwerfer hat mehrere Programme hinterlegt die Sie aktivieren können in der Geschwindigkeit verändern können sowie in der Programmdauer einstellen können Wechseln Sie den Mode bis im Display AUTO erscheint Dr...

Отзывы: