background image

Installation and User's Manual

IMPORTANT INFORMATION

IMPORTANT INFORMATION

            When using electrical equipment, basic safety precautions should always be followed including the following:

a. READ AND FOLLOW ALL SAFETY INSTRUCTIONS.

b. Do not mount near gas or electric heaters.

c. Equipment should be mounted in locations and at heights where it will not readily be subjected to

tampering  by unauthorized personnel.

d. The use of accessory equipment not recommended by the manufacturer may cause an unsafe

condition.

e. Do not use this equipment for other than intended use.

f. Refer service to qualified personnel.

            

SAVE THESE INSTRUCTIONS

.

WARNING

: You must have  access to a main circuit breaker or other power disconnect device before 

installing any wiring. Be sure that power is disconnected by removing fuses or turning the main circuit
breaker off  before  installation.  Installing  the device with  power on  may  expose  you to  dangerous 
voltages and damage the device. A qualified  electrician must perform this installation.

WARNING

: Refer to national Electrical Code and local codes for cable specifications. Failure to use 

proper cable can result in damage to equipment or danger to personnel.

WARNING

: T

his equipment is intended for installation in accordance with the National Electric Code

 and local regulations. It  is  also  intended  for  installation  in  indoor  applications  only.  Before any

 

electrical  work is  performed, disconnect  power  at  the  circuit breaker or  remove the fuse to avoid

shock or damage to the control. It is recommended that a qualified electrician perform this installation.

Warnings and Notices

Additional

 

Resources

 

for

 

DMX512

For

 

more

 

information

 

on

 

installing

 

DMX512 control

 

systems

the

 

following publication

 

is

 

available

 

for

 

purchase

 

from

 

the

 

United

 

States

 

Institute

 

for

 

Theatre

 

Technology

 (

USITT

), "

Recommended

 

Practice

 

for

 

DMX512

A

 

Guide

for

 

Users

 

and

 

Installers

,  

2nd

 

edition

" (

ISBN

9780955703522

). 

USITT

 

Contact

 

Information

:

USITT

315

 

South

 

Crouse

 

Avenue

Suite

 

200

Syracuse

NY

 

13210-1844

Phone

1.800.938.7488 or 1.315.463.6463

www

.

usitt

.

org

Showline

 

Limited

 

Two

-

Year

 

Warranty

Showline

 

offers

 

a

 

two

-

year limited

 

warranty

 

of

 

its

 

luminaires

 

against

 

defects

 

in

 

materials

 

or

 

workmanship

 

from

 

the

 

date

 

of

 

delivery

A

 

copy

 

of

 

Showline

 

two

-

year

 

limited

 

warranty

 

containing

 

specific

 

terms

 

and

 

conditions

 

can

 

be

obtained

 

by

 

contacting

 

your local

 

Showline

 

office

SL STRIP 10 IP LED Luminaires

Содержание SL STRIP 10IP

Страница 1: ...SL STRIP 10IP LED LUMINAIRE ...

Страница 2: ...www philips com showline Version as of 17th Sep 2015 SL STRIP 10IP User s Manual 2015 Vari Lite Document Number SL STRIP 10IP LED Luminaires User Manual ...

Страница 3: ... Failure to use proper cable can result in damage to equipment or danger to personnel WARNING This equipment is intended for installation in accordance with the National Electric Code and local regulations It is also intended for installation in indoor applications only Before any electrical work is performed disconnect power at the circuit breaker or remove the fuse to avoid shock or damage to th...

Страница 4: ...ca market only AC Input cable 1500mm For International market only AC Output cable 1000mm For International market only AC Output cable 1000mm For US Canada and Latin America market only DMX Input cable 1000mm DMX Input cable 1000mm DMX Output cable 1000mm DMX Output cable 1000mm North American Market International Market Installation and User s Manual SL STRIP 10 IP LED Luminaires Note The SL STR...

Страница 5: ...anging Application SAFETY CABLE Is sold separately and recommended for all hanging installations and may be required by national and local codes Use the provided safety cable anchor points to attach the safety cable for this luminaire SL STRIP 10IP LED Luminaires are provided with Trunnion Arms The user can tighten the wing screws manually For hanging applications it is recommended and may be requ...

Страница 6: ...ower source using an AC input cable For wiring of AC input connector refer to Connecting SL STRIP 10IP LED Luminaires to AC Power Connection from the AC output of another SL STRIP 10IP LED Luminaire When using this method it is very important not to connect any other type of equipment Connecting SL STRIP 10IP LED Luminaires to AC Power WARNING WARNING WARNING Only connect other SL STRIP 10IP LED L...

Страница 7: ...tance to flammable materials 0 2m Distance de sécurité minimale aux matériaux inflammables 0 2 m Minimum safety distance from lighted objects 0 5m Distance de sécurité minimale des objets illuminés 0 5m Maximum operating temperature of enclosure surface is 60 C Température de fonctionnement maximale de la surface de l enceinte est de 60 C DO NOT STARE AT THE OPERATING LIGHT SOURCE 警 告 机器在接电前请参阅安装 ...

Страница 8: ... 000 100 000 255 000 255 000 255 000 255 To set the initial DMX receiving address To set the DMX Control Mode To set the status of the fixture when there is no DMX input To set the output intensity of the red To set the output intensity of the green To set the output intensity of the blue Can be set as ON or OFF To set the output intensity of the cool white To select a built in program To set the ...

Страница 9: ...L STRIP 10IP DMX Mapping RGBW 16 Bit Mode SL STRIP 10IP DMX Mapping RGBW 8 Bit Mode OPERATION MODES 6 Red_1 10 Green_1 10 Blue_1 10 White_1 10 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Страница 10: ...select and activate the desired chase Press the MODE button to select and activate the DMX menu Set the DMX address DMX Bit DMX Fade and DMX Channel Press the MENU button to select and enter the desired menu The DMX Address Mode is indicated by DMX Addr followed by three digits 001 512 Press the UP and DOWN buttons to change the DMX Address Value Press the MENU button to select and activate the DM...

Страница 11: ...e Speed Menu Press the MENU button to select the Chase Speed menu In this menu you can adjust the program chase speed Press the UP and DOWN buttons to adjust the chase speed from 01 to 99 A value of 99 will give you the fastest chase speed approx 1 10th of a second A value of 01 will give you the slowest chase speed once every 30 seconds Press the MENU button to select the Chase Dimmer menu In thi...

Страница 12: ...tline and describe all the RDM parameters IDs associated with SL STRIP 10IP Table 1 SL STRIP 10IP RDM Parameter IDs SL STRIP 10IP SL STRIP 10IP 0x1000 Vari Lite Asia 0x0105 RDM PARAMETER IDS 9 82H Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Страница 13: ...Table 1 SL STRIP 10IP RDM Parameter IDs RDM PARAMETER IDS 10 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Страница 14: ...IDs Manufacturer Defind PIDs range is 0x8000 0xffdf See Table A 3 ANSI E1 20 2010 Get Allowed SET Allowed RDM Parameter Id s TYPE UNIT PREFIX MIN MAX DEFAULT DESCRIPTION Chase program Chase Dimmer DMX Fade on off Manual red Manual green Manual blue Chase Speed Manual white Chase Fade Calibration On off 8A00H 8AA1H 8AB2H 8A0CH 8AB1H 8AA0H 8A92H 8AA2H 8A94H 8A44H U8 U8 U8 U8 U8 U8 U8 U8 U8 U8 1 1 0 ...

Страница 15: ... to 104 Degrees F 6 degree native beam angle 15 25 or 11 x 38 degree diffuser lens 2240 lumens 2700 6500K user adjustable 100V to 240V 10 auto ranging 150 Watts max 50 60Hz DMX512 1990 DMX512A RDM On Board Menu Source Beam Angle Light Output Color Temerature Input Voltage Power Consumption Frequency Control Protocols CE C Tick marked and ETL listed IP65 Compliance IP Rating Note Common model speci...

Страница 16: ...13 Installation and User s Manual SL STRIP 10 IP LED Luminaires ...

Страница 17: ...Industrial Centre No 41 49 Kwai Cheong Road Kwai Chung N T Hong Kong Tel 852 2796 9786 Fax 852 2798 6545 Auckland 19 21 Kawana Street Northcote Auckland 0627 New Zealand Tel 64 9 481 0100 Fax 64 9 481 0101 Europe Rondweg zuid 85 Winterswijk 7012 JD The Netherlands Tel 31 0 543 542516 C 2015 Vari Lite ...