Installation 

 

Safety Instructions for Installation 

 

WARNING 
Incorrect installation can cause serious injuries and damage of property. 

Installation must be carried out only by instructed or skilled persons. 

Follow all applicable European, national and local safety regulations concerning electrical installations. 

 

Attention 
Make sure there is enough space for ventilation around the device. 

 

Installation Site Requirements 

 

The device must be installed only indoors. 

 

The device can be placed on a flat surface or mounted in a standard 19-inch rack. 

 

The maximum ambient temperature t

a

 = 35 °C must never be exceeded. 

 

The relative humidity must not exceed 50 % with an ambient temperature of 35 °C. 

 

Rack Mounting 

The device can be mounted in a standard 19-inch rack. The device requires 6 rack units (RU) of space. 
1 rack unit is 44,45 mm high. 

Make sure that the rack is sufficiently secured to prevent it from becoming unstable or falling over. 

To mount the device in a two-post rack, follow the steps below: 

01)

 

Insert 4 cage nuts in the openings on the rack posts where you want to mount the device. 

02)

 

Position the device in front of the rack posts so that the 4 mounting openings on the flanges face the 
openings on the rack posts with cage nuts. 

03)

 

Using a screwdriver, mount the device to the rack posts with 4 screws. 

 

Connecting to Power Supply 

 

DANGER 
Electric shock caused by short-circuit
 

The device accepts AC mains power at 400 V and 50/60 Hz. Do not supply power at any other voltage or 
frequency to the device. 

This device falls under IEC protection class I. Make sure that the device is always electrically connected 
to the ground (earth). 

Before connecting the device to the socket-outlet: 

 

Make sure that the power supply matches the input voltage specified on the information label on 
the device. 

 

Make sure that the socket-outlet has ground (earth) connection. 

Connect the device to the socket-outlet with the power plug or a 3 x 125 A CEE H07RN-F cable. 

 

 

Содержание 50667

Страница 1: ...PSA 125A4C Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 50667 USER MANUAL ENGLISH V2...

Страница 2: ...ce Non observance of the instructions in this user manual may result in serious injuries and damage of property 2021 Showgear All rights reserved No part of this document may be copied published or ot...

Страница 3: ...ecifications 10 Dimensions 10 4 Installation 11 Safety Instructions for Installation 11 Installation Site Requirements 11 Rack Mounting 11 Connecting to Power Supply 11 Schematic Overview 12 5 Setup a...

Страница 4: ...a 3 phase power distribution unit in theaters entertainment facilities public venues and similar It is suitable only for indoor use This device is not suitable for households and residential building...

Страница 5: ...ration and use of the product Important Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Informatio...

Страница 6: ...d to ground earth Connect the device only to a socket outlet with ground earth connection Do not cover the ground earth connection Do not bypass the thermostatic switch or fuses Do not let the power c...

Страница 7: ...venues and similar Any incorrect use may lead to hazardous situations and result in injuries and material damage This device is not suitable for households and residential buildings This device does n...

Страница 8: ...rson or are supervised by a skilled person for specific tasks and work activities associated with the installation service and maintenance of this product so that they can identify risks and take prec...

Страница 9: ...ts and a 5 pin CEE input The maximum allowed current load is 125 A per phase The maximum allowed current load per output is 3 x 63 A Front View Fig 02 Residual Current Device Output 1 Main Circuit Bre...

Страница 10: ...9 PSA 125A4C Product code 50667 Back View Fig 03 5 pin CEE OUT 1 5 pin CEE OUT 2 5 pin CEE OUT 3 5 pin CEE OUT 4 5 pin CEE power IN...

Страница 11: ...uts Power connector IN 1 x CEE male 125 A 3P N PE 400 V AC 50 60Hz Power connector OUT 4 x CEE female 63 A 3P N PE 230 V AC 50 60 Hz Physical Dimensions 482 x 400 x 267 mm LxWxH 19 x 6 U LxH Weight 17...

Страница 12: ...sufficiently secured to prevent it from becoming unstable or falling over To mount the device in a two post rack follow the steps below 01 Insert 4 cage nuts in the openings on the rack posts where yo...

Страница 13: ...y for indoor use This device is not suitable for households and residential buildings This device is designed for use in environment B Any other use not mentioned under intended use is regarded as non...

Страница 14: ...ibed in the table Problem Probable cause s Solution The device does not function at all No power to the device Check if power is switched on and cables are plugged in The residual current device or th...

Страница 15: ...transport the device if possible Clean the device before storing Follow the cleaning instructions in chapter 7 2 1 Basic Cleaning Instructions on page 14 Store the device in the original packaging if...

Страница 16: ...2021 Showgear...

Отзывы: