PSA-125A4C 

Highlite International B.V. – Vestastraat 2 – 6468 EX – Kerkrade – the Netherlands 

Product code: 50667 

USER MANUAL 

ENGLISH 

V2 

Содержание 50667

Страница 1: ...PSA 125A4C Highlite International B V Vestastraat 2 6468 EX Kerkrade the Netherlands Product code 50667 USER MANUAL ENGLISH V2...

Страница 2: ...ce Non observance of the instructions in this user manual may result in serious injuries and damage of property 2021 Showgear All rights reserved No part of this document may be copied published or ot...

Страница 3: ...ecifications 10 Dimensions 10 4 Installation 11 Safety Instructions for Installation 11 Installation Site Requirements 11 Rack Mounting 11 Connecting to Power Supply 11 Schematic Overview 12 5 Setup a...

Страница 4: ...a 3 phase power distribution unit in theaters entertainment facilities public venues and similar It is suitable only for indoor use This device is not suitable for households and residential building...

Страница 5: ...ration and use of the product Important Read and observe the instructions in this document Electrical hazard Provides important information about the disposal of this product Symbols on the Informatio...

Страница 6: ...d to ground earth Connect the device only to a socket outlet with ground earth connection Do not cover the ground earth connection Do not bypass the thermostatic switch or fuses Do not let the power c...

Страница 7: ...venues and similar Any incorrect use may lead to hazardous situations and result in injuries and material damage This device is not suitable for households and residential buildings This device does n...

Страница 8: ...rson or are supervised by a skilled person for specific tasks and work activities associated with the installation service and maintenance of this product so that they can identify risks and take prec...

Страница 9: ...ts and a 5 pin CEE input The maximum allowed current load is 125 A per phase The maximum allowed current load per output is 3 x 63 A Front View Fig 02 Residual Current Device Output 1 Main Circuit Bre...

Страница 10: ...9 PSA 125A4C Product code 50667 Back View Fig 03 5 pin CEE OUT 1 5 pin CEE OUT 2 5 pin CEE OUT 3 5 pin CEE OUT 4 5 pin CEE power IN...

Страница 11: ...uts Power connector IN 1 x CEE male 125 A 3P N PE 400 V AC 50 60Hz Power connector OUT 4 x CEE female 63 A 3P N PE 230 V AC 50 60 Hz Physical Dimensions 482 x 400 x 267 mm LxWxH 19 x 6 U LxH Weight 17...

Страница 12: ...sufficiently secured to prevent it from becoming unstable or falling over To mount the device in a two post rack follow the steps below 01 Insert 4 cage nuts in the openings on the rack posts where yo...

Страница 13: ...y for indoor use This device is not suitable for households and residential buildings This device is designed for use in environment B Any other use not mentioned under intended use is regarded as non...

Страница 14: ...ibed in the table Problem Probable cause s Solution The device does not function at all No power to the device Check if power is switched on and cables are plugged in The residual current device or th...