Shop-Vac BMB series Скачать руководство пользователя страница 2

(Your casters may look different)

With Caster Feet

You will find four caster feet and casters 

(b.)

and four screws with your wet/dry vacuum.

Assemble as follows:
1. With cord disconnected from receptacle and tank cover removed, turn tank upside

down so that bottom is facing up.

2. With front of tank facing you, take caster feet with caster marked with the letter A 

(Figure

1) 

and place in slots on left front and right rear of tank also marked with the letter A

(Figure 2) 

and secure with screws provided.

(Figure 3).

3. Take caster feet with casters marked with the letter B 

(Figure 4)

and place on right

front and left rear of tank also marked with the letter B 

(Figure 5)

and secure with screws provided.

(Figure 6)

4. Return tank to upright position.

This appliance must be grounded. If it should malfunction or breakdown, grounding pro-
vides a path of least resistance for electric current to reduce the risk of electric shock.
This appliance is equipped with a cord having an equipment-grounding conductor and
grounding plug. The plug must be inserted into an appropriate outlet that is properly
installed and grounded in accordance with all local codes and ordinances.

WARNING

– IMPROPER CONNECTION OF THE

EQUIPMENT-GROUNDING CONDUCTOR CAN RESULT
IN A RISK OF ELECTRIC SHOCK. CHECK WITH A
QUALIFIED ELECTRICIAN OR SERVICE PERSON IF
YOU ARE IN DOUBT AS TO WHETHER THE OUTLET IS
PROPERLY GROUNDED. DO NOT MODIFY THE PLUG
PROVIDED WITH THE APPLIANCE – IF IT WILL NOT
FIT THE OUTLET, HAVE A PROPER OUTLET
INSTALLED BY A QUALIFIED ELECTRICIAN.

This appliance is for use on a nomi-
nal 120-volt circuit, and has a
grounded plug that looks like the plug
illustrated in 

sketch A

.

NOTE:

IN CANADA, THE USE OF A

TEMPORARY ADAPTER IS NOT PER-
MITTED BY THE CANADIAN
ELECTRICAL CODE.

When using the appliance at a
distance where an extension cord
becomes necessary, a 3-conduc-
tor grounding cord of adequate
size must be used for safety, and
to prevent loss of power and over-
heating. Use the table below to
determine A.W.G.

wire size

required. To determine ampere
rating of your vacuum, refer to nameplate located on rear of motor cover.
Before using appliance, inspect power cord for loose or exposed wires and damaged
insulation. Make any needed repairs or replacements before using your appliance. Use
only three-wire outdoor extension cords which have three-prong grounding-type plugs
and three-pole receptacles which accept the extension cord’s plug. When vacuuming
liquids, be sure the extension cord connection does not come in contact with the liquid.

NOTE:

STATIC SHOCKS ARE COMMON IN DRY AREAS OR WHEN THE RELATIVE HUMIDITY OF THE

AIR IS LOW. THIS IS ONLY TEMPORARY AND DOES NOT AFFECT THE USE OF THE APPLIANCE. TO
REDUCE THE FREQUENCY OF STATIC SHOCKS IN YOUR HOME, THE BEST  REMEDY IS TO ADD
MOISTURE TO THE AIR WITH A CONSOLE OR INSTALLED HUMIDIFIER.

!

SAVE THESE INSTRUCTIONS

GROUNDING INSTRUCTIONS

EXTENSION CORDS

Volts

Total length of cord in feet

120V

 Ampere Rating

   More    Not More

Than        Than

0-6

6-10

10-12
12-16

25

50

100

150

AWG

18
18
16
14

16
16
16
12

16
14
14

14
12
12

Not recommended

1. Take off tank cover and remove any accessories which may have been shipped in the tank.
2. Attach casters following instructions in the manual.
3. Before replacing tank cover, please refer to Dry Pick-Up or Wet Pick-Up Operation in this

manual to ensure you have the proper filters installed for your cleaning operation.

4. Replace tank cover, and apply pressure with thumb to each latch until it snaps tightly in

place. Make sure all lid latches are clamped securely.

5. Slip cleaner end of flexible hose into the intake port.
6. Attach the extension wands to the accessory end of the hose.
7. Attach one of the cleaning accessories (depending on your cleaning requirements) to the

extension wands.

8. Plug the cord into the wall outlet. Your cleaner is ready for use.

NOTE:

MANY MORE USEFUL TOOLS ARE AVAILABLE AT YOUR LOCAL DEALER, SERVICE CEN-

TER, OR USE THE ENCLOSED MAIL ORDER FORM FOR DIRECT PURCHASE FROM SHOP VAC.

Without Caster Feet

You will find  four casters 

(a.)

with your wet/dry vacuum. Assemble as follows:

1. With cord disconnected from receptacle and tank cover removed, turn tank upside

down so that bottom is facing up.

2. Insert casters into bottom of tank by placing stem of caster into holes provided and

applying pressure until caster snaps into place 

(Figure 1)

.

Not all units are equipped with caster feet. Follow the instructions, which apply to
your specific unit.

CASTER ASSEMBLY

a.

1.

A

A

A

A

2.

B

3.

B

B

4.

B

B

B

B

A

A

5.

6.

b.

A

A

1.

UNPACKING AND SET-UP

WARNING

– ALWAYS DISCONNECT THE PLUG

FROM THE WALL OUTLET BEFORE REMOVING THE TANK
COVER.

To pick up dust and dry material, you must install foam sleeve and reusable dry fil-
ter to ensure proper filtration. If the vacuum has been used to pick up liquids, the
foam sleeve must be cleaned and dried before installing for dry pick up. With tank
cover in an upside down position, slide foam sleeve down over lid cage pulling until
foam sleeve completely covers lid cage 

(Figure 7)

. NOTE: Bottom of foam sleeve

must be positioned on the OUTSIDE of groove around lid cage for the reusable dry
filter to fit properly 

(Figure 8, 8a)

. Center the reusable dry filter on lid cage 

(Figure

9)

, slide mounting ring down over filter until ring is positioned against the ribs of the

lid cage 

(Figure 10)

. The reusable dry filter should always be in position over the

foam sleeve for dry pick-up. To remove the filter for cleaning, remove mounting ring
and filter from lid cage 

(Figure 11)

. To clean the reusable dry filter, shake off excess

dirt and dust or (depending on the condition of the filter) rinse with water. Allow the
filter to dry completely and re-install. DO NOT MACHINE WASH OR DRY.

IMPORTANT:

BEFORE INSTALLING REUSABLE FILTER BE SURE THAT FOAM SLEEVE

IS OUTSIDE OF GROOVE AND AROUND LID CAGE.

(Figure 8, 8a)

INSTALLING FOAM SLEEVE AND

REUSABLE DRY FILTER

(Not standard with all models)

7.

8.

8a

9.

10.

11.

Содержание BMB series

Страница 1: ...t 7 16 wrench or socket When using an electrical appliance basic precautions should always be followed including the following READ ALL INSTRUCTIONS BEFORE USING THIS APPLIANCE WARNING TO REDUCE THE RISK OF FIRE ELECTRIC SHOCK OR INJURY 1 Do not leave appliance when plugged in Unplug from outlet when not in use and before servicing Connect to a properly grounded outlet only See Grounding Instructi...

Страница 2: ...NG INSTRUCTIONS EXTENSION CORDS Volts Total length of cord in feet 120V Ampere Rating More Not More Than Than 0 6 6 10 10 12 12 16 25 50 100 150 AWG 18 18 16 14 16 16 16 12 16 14 14 14 12 12 Not recommended 1 Take off tank cover and remove any accessories which may have been shipped in the tank 2 Attach casters following instructions in the manual 3 Before replacing tank cover please refer to Dry ...

Страница 3: ...und the cord wraps provided on the tank cover on rear of unit Figure 15 EMPTYING LIQUID WASTES FROM THE TANK AUTOMATIC SUCTION SHUT OFF STORAGE 15 BLOWER SAFETY 1 Never operate the portable blower in wet or damp condi tions Do not use in rain 2 Keep area of operation clear of all persons particularly small children and pets 3 Dress properly Do not wear loose clothing or jewelry Always wear substan...

Страница 4: ...t 19 Ne pas laisser le cordon électrique sur le plancher lorsque l on a fini d utiliser l aspirateur car on risque de s accrocher dedans et de tomber 20 Il faut être extrêmement prudent lorsque l on vide un réservoir lourdement chargé 21 Pour empêcher toute combustion spontanée vider le réservoir après chaque utilisation de l aspirateur 22 L utilisation d un aspirateur utilitaire peut causer la pr...

Страница 5: ...ENDROITS TOUT AUTOUR DE SA CIRCONFÉRENCE S ASSURER QUE LE FIL TRE DISQUE SEC RÉUTILISABLE RECOUVRE COMPLÈTEMENT LE FILTRE EN MOUSSE S ASSURER QUE TOUS LES BORDS DU FILTRE SEC RÉUTILISABLE SONT BIEN RETENUS SOUS LA BAGUE DE FIXATION ATTENTION GARDER LES FILTRES SECS PROPRES POSE DU SAC FILTRE JETABLE Pas standard sur tous les modèles 1 À n utiliser que pour aspirer des déchets secs 2 Le cordon élec...

Страница 6: ...LISA TION DU SOUFFLEUR 1 Ne jamais utiliser le souffleur portatif dans des condi tions humides Ne jamais l utiliser lorsqu il pleut 2 Ne jamais permettre à quiconque de s approcher de la zone où l on utilise le souffleur en particulier les petits enfants et les animaux familiers 3 Il faut s habiller adéquatement Ne pas porter de vête ments amples ni de bijoux Toujours porter des souliers convenabl...

Отзывы: