background image

TROUBLE

POSSIBLE CAUSE

REMEDY

TROUBLESHOOTING

WARNING - 

IF ANY OF THE MOTOR HOUSING PARTS SHOULD BECOME DETACHED OR BROKEN, 

EXPOSING THE MOTOR OR ANY OTHER ELECTRICAL COMPONENTS, OPERATION SHOULD BE 

DISCONTINUED IMMEDIATELY TO AVOID PERSONAL INJURY OR FURTHER DAMAGE TO THE VACUUM. 

REPAIRS SHOULD BE MADE BEFORE REUSING THE VACUUM.

Suction weakens or 

cleaner runs hot.

Clogged filter

Brush dirt from filter. If condition continues, change filter.

Air leak

Check all fittings for tight fit (nozzles, hoses, etc.).

Check that tank cover is sealed properly.

Obstruction in

hose or nozzle

Check nozzle, hose, etc. for obstructions, and remove if present.

Misting in the exhaust air.

Saturated filter

Replace saturated filter with a dry filter.

87555-09

LUBRICATION

No lubrication is necessary as the motor is equipped with lifetime lubricated bearings.

STORAGE

Before storing your vacuum cleaner, the tank should be emptied and cleaned. The power cord can be wrapped around 

the cord wraps provided on the tank cover on rear of unit. 

The cleaner should be stored indoors

Liquid waste may be emptied by removing the tank drain. To empty, turn unit off and remove plug from wall receptacle. Remove the drain cap and 

deposit the liquid waste contents in a suitable drain.  After the tank is empty, return the drain cap to its original position. To continue use, plug the 

cord into the wall receptacle and turn the unit on.

EMPTYING LIQUID WASTE FROM THE TANK

AUTOMATIC SUCTION SHUT-OFF

The cleaner is equipped with an automatic shut-off that operates when picking up liquids. As the level of the liquid rises, an internal float rises

until it seats itself against a seal at the intake of the motor, shutting off suction. When this happens, the motor will develop a higher than 

normal pitch noise. To continue use, empty the liquid waste from the tank as outlined in the previous paragraph.

NOTE:

  IF ACCIDENTALLY TIPPED OVER, THE VACUUM COULD LOSE SUCTION. IF THIS OCCURS, PLACE VAC IN UPRIGHT POSITION AND TURN

SWITCH OFF. THIS WILL ALLOW THE FLOAT TO RETURN TO ITS NORMAL POSITION, AND YOU WILL BE ABLE TO CONTINUE OPERATION.   

WARNING - 

ALWAYS WEAR EYE PROTECTION TO PREVENT ROCKS OR DEBRIS FROM BEING 

BLOWN OR RICOCHETING INTO THE EYES OR FACE WHICH CAN RESULT IN SERIOUS INJURY.

BLOWER FEATURE

This vacuum can be used as a powerful blower. To use your unit as a blower insert hose end into blower port on rear of unit. 

Clear hose of any obstructions before attaching to blower port. Caution should be used when using as a blower due to the 