background image

31

32

PUMP OPERATION

PUMP (VAC) FEATURE

WET PICK UP AND PUMP ASSEMBLY

Please Note – the pump feature is designed to pump water out of the vacuum tank. It is not intended to be a continuous 

running pump system. Wet (liquid) vacuum pick up volume is greater than pump discharge volume and vacuum will 

automatically shut-off when tank is full. Use Re-Set Switch (ON/OFF) to begin pumping again. Please use the following 

directions for operation of this unique and beneficial feature. 

WARNING - 

TO REDUCE THE RISK OF ELECTRICAL SHOCK, DO NOT DIRECT DISCHARGE STREAM 

   

     AT UNIT!

1.  Always disconnect the plug from the wall receptacle before removing the tank cover 

(Figure 33).

2.  Remove tank cover and cartridge filter. Tank should also be cleaned of any dirt or debris 

(Figure 34).

3.  Ensure that the foam sleeve is in place for wet pick up

 (Figure 35).

4  Be sure the opening of the inlet deflector is facing the top of the tank 

(Figure 36).

5.  Insert tube provided into pick up cage pushing until tube comes to a stop 

(Figure 37).

6. Take pick up assembly and insert tube into hole in bottom of lid cage pushing until assembly comes to a stop 

(Figure 38). NOTE: 

Do not  

 

 attempt to pump without pick up cage in place or screen on pick up cage. Failure to do could result in damage to pump.

WARNING - 

THE CARTRIDGE FILTER IS NOT COMPATIBLE WHEN UTILIZING THE PUMP PICK UP 

   

     ASSEMBLY.

7.  Replace tank cover and secure lid latches.
8.  To prevent unwanted discharge of water leave cap in place or attach garden hose until you are ready to empty tank.
9.  Once you are ready to begin pumping, remove outlet fitting cover and connect a standard garden hose (not supplied) to outlet fitting 

  (Figure 39).       

             

10. Attach the 32mm (1-1/4") hose to tank inlet.     
11. Plug vacuum into wall outlet and push the ON switch button.

 I=ON, O=OFF   

12. Start wet pick up. In order to prime the pump feature, you will need at least 10cm (4") of water in the bottom of tank. At this time the unit will   

  automatically begin pumping. The unit will automatically shut off when full.
13. To empty a full tank by pumping, first remove the vacuum hose from the liquid. Do not empty liquid from hose back into tank. This will cause    

  the unit to over fill and misting will occur through the exhaust port.
14. The ON switch must be manually held in the ON position for approximately 10-15 seconds to allow the water level to be reduced sufficiently,    

  and then pumping will continue automatically. The unit will continue to discharge liquid until there is about 10cm (4") left in the tank. 

NOTE:  

 

  WET PICK UP VOLUME IS GREATER THAN THE DISCHARGE VOLUME AND STEP 14 MAY NEED TO BE REPEATED IF THE UNIT SHOULD SHUT  

 

  OFF.
15. After wet pick up and pumping has been completed, the remaining liquid should be emptied from the tank and the pump pick up assembly    

  should be removed.  
                                                       