background image

13

OPERATING  

HEATER

 

FOR YOUR SAFETY

  

 

 

READ BEFORE LIGHTING

   

 

 WARNING: If you do not follow 

A.  This   appliance  has  a  

pilot  which  must  

be 

lighted by  hand.  When

g

n

i

t

h

g

i

 the  

pilot, 

follow these instructions exactly.

B.  BEFO RE LIGHTING smell  all around  the 

a pp liance  a rea  for gas.  Be sure  to smell  nex t 

to the  

oor  because  some   gas  is heavier  than 

air

 and will settle on the floor.

 

WHAT TO DO I F YOU SMELL GAS

• Do not try to light any appliance.
• Do not  touch  any  electric  switch;  do  not 

use any phone in your building.

• Immediately  call you r gas  supplier  from 

a  n eig hb o r’s  pho n e.

 

F o llow  th e   gas

supplie r’s instructions.

• If you  cannot  re a ch  you r gas  supplie r, call

the fi

re department.

C.

 

Use  only your  hand  to push  in or turn  the 

ga s   control  knob.  Ne ve r  use   tools .  If  the 

 knob will  not  push  in or turn by hand,  don’t 

try to repair  it, call a  

qualified

 service  techn-

ician  or

s

a

 supplie r . Fo rce  or attempted 

repair  may  r

esult in a fi

re o r  explosion.

D.  Do  not   use   this   appliance  if  any   part   has 

been   under   wat e r.  Imm ediat el y   call   a 

qualified

  service   technician   to  inspect   the 

a ppliance   and   to  replace   any  par t  of  the 
control system  and  any  gas  cont rol which 
has been under water

LIGHTING

 

INSTRUCTIONS

 WARNING:

  If 

fireplace

 

has

 

glass

 

doors, never

 

operate

 

this

 

heater

 

with glass

 

doors

 

closed.

 If you 

opera

t

e

 h

ea

t

er

 with 

doo

rs

 

c

lo

se

d

, heat

 

buildup

 

inside

 

fireplace 

will 

ca

u

se

 gl

ass

 to bu

rs

t

.

 

M

a

k

e s

u

re

 th

ere

 

are

 no ob

s

t

r

u

c

t

ions      

across openings of fireplace.

 

You 

must

 

operate

 

this

 

heater 

with 

a

  fi

rep

l

ace

 

scree

n  in 

p

l

ace.

  M

a

k

e

 

s

u

re

  fi

rep

l

ace screen

 

is

 

closed

 

before

 

running heater.   

NOTICE: Du

r

ing initi

a

l o

pera

tionof 

new

 

heater,

 

burning

 

logs

 

will give

 off 

a

 

paper-burning

 

smell. Orange

 

flame

 will 

also

 

be

 

present.

 

Open

 

damper

 

or

 

win-

dow 

to vent

 

smell.

 

This

 will only 

last

 

a     

few hours.

No

te:

 

 

heater with the chimney damper closed.

 

This will 

 

 

 

put all the heat intothe room. However, there may be 

 

 

 

 

 

 

 

 

 

can open the chimney damper (if you have one) fully
or partially to release some of the heat. 

        WARNING: 

Damper

 

handle will

 

be

 

hot  if 

heater

 

has

 

been running.  

these

 

instructions

 

exactl

y

, a

 

fire

 

or

 

explosion

 

may

 

result causing

 

prop-

erty

 

damage,

 

personal injury or loss 

of life.  

Homeowners generally prefer to operate their

times you will desire the full flames of the HI heat  

settings but will find the heat output excessive. You 

REMOTE - READY 

MODELS

 

1.

 

STOP! Read the safety information from this page
column 1.

2.

 

Make sure equipment shutoff valve is fully open..

3.

 

Set selector switch in the OFF position.

        WARNING:

 Burners will come on 

 

 

   

 

 

automatically within one minute after

the pilot is lit, when

 

the selector switch 

is in the on position

Содержание GERRR18LP

Страница 1: ...MER Retain this manual for future reference This appliance may be installed in an aftermarket permanently located manu factured mobile home where not prohib ited by local codes This appliance is only for use with the type of gas indicated on the rating plate This app liance is not convertible for use with other gases Aftermarket Completion of sale not for purpose of resale from the manufacturer Th...

Страница 2: ...blow directlyintotheappliance Avoidanydrafts that alter burner flame patterns Ceiling fans can create drafts that alter burner flamepatterns Alteredburnerpatternscan cause sooting WARNING Do not use a blower insert heat exchanger insert or other accessory not approved for use with this appliance Due to high temperatures the appliance should be located out of traffic and away from furniture and draper...

Страница 3: ...ance has an Oxygen Depletion Sensing ODS safety shutoff system The ODS shuts down the fireplace if not enough fresh air is available See Air for Combustion and Ventilation pages 4 through 6 If appliance keeps shutting off see Troubleshooting pages 17 through 20 11 Do not run appliance where flammable liquids or vapors are used or stored under dusty conditions 12 Do not use this appliance to cook fo...

Страница 4: ...d a control valve The thermostat will automatically modulate the heat output to maintain a consistent room temperature This results in greater heater comfort This can also result in lower gas bills PROVIDING ADEQUATE VENTILATION The following are excerpts from National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation All spaces in homes fall into one of the followin...

Страница 5: ...ls or ducts You must provide two permanent openings one within 12 of the ceiling and one within 12 of the floor Connect these items directly to the outdoors or spaces open to the s e c a p s l w a r c d n a s c i t t a e d u l c n i s e c a p s e s e h T s r o o d t u o Follow the National Fuel Gas Code ANSI Z223 1 NFPA 54 Section 5 3 Air for Combustion and Ventilation for required size of ventilat...

Страница 6: ...ay be operated does not meet the required volume for indoor combustion air combustion and ventilation air shall be provided by one of the methods described intheNationalFuelGasCode ANSIZ223 1 NFPA 54 the International Fuel Gas Code or applicable local codes CONTINUED VENTED OPERATION Note When used as a vented heater appliance must be installed only in a solid fuel burning fireplace with a working...

Страница 7: ...this is beneficial installing appliance in rooms without enough ventilation air may cause mildew to form from too much moisture See Air for Combustion and Ventilation page 4 CHECK GAS TYPE Use the correct gas type natural or propane LP for your appliance If your gas supply is not correct or if you do not know your gas type do not install appliance INSTALLATION ITEMS NEEDED Before installing applian...

Страница 8: ...lator damage could occur For propane LP gas the installer must supply an external regulator The external regulator will reduce incoming gas pressure Youmustreduceincominggaspressuretobetween 11 and 14 of water If you do not reduce incoming gas pressure heater regulator damage could occur Install the external regulator with the vent pointing down as shown in Figure 4 Pointing the vent down protects...

Страница 9: ...nd that you install a sediment trap in supply line as shown in Figure 5 Locate sediment trap where it is within reach for cleaning Install in piping system between fuel supply and appliance Locate sediment trap where trapped matter is not likely to freeze A sediment trap traps moisture and contaminants This keeps them from going into appliance gas controls If sediment trap is not installed or is i...

Страница 10: ...as valve located on or near gas meter of natural gas or using compressed air 3 Check all joints from gas meter to equipment shutoff valve for natural gas or propane LP supply to equipment shutoff valve for propane LP Apply noncorrosive leak detection fluid to all joints Bubbles forming show a leak 4 Correct all leaks at once CONTINUED 10 OPTIONAL REMOTE CONTROL SET INSTALLATION AND OPERATION COMMUN...

Страница 11: ...Proper Log Placement for Discovery Elm 18 Models Log 2 Log 6 Log 1 Log 5 Log 7 If you have any questions please call 800 229 5647 GERRR18 MODELS Log 3 Log 4 11 ...

Страница 12: ...Proper Log Placement for Golden Eclipse 24 Models Log 2 Log 6 Log 1 Log 5 Log 7 If you have any questions please call 800 229 5647 GERRR24 MODELS Log 3 Log 4 12 ...

Страница 13: ...ONS WARNING If fireplace has glass doors never operate this heater with glass doors closed If you operateheaterwith doorsclosed heat buildup inside fireplace willcauseglasstoburst Make suretherearenoobstructions across openings of fireplace You must operate this heater with a fireplace screen in place Make sure fireplace screen is closed before running heater NOTICE Duringinitialoperationof new heate...

Страница 14: ...ton This will light pilot The pilot is attached Note If pilot does not light no spark contact a qual ified service person or gas supplier for repairs Until re with match see Manual Lighting Procedure page 15 8 Keep control knob pressed in for 30 seconds after lighting pilot After 30 seconds release control knob If control knob does not pop out when released contact a qualified service person or gas...

Страница 15: ... switch see Fig ure 10 to the ON position Replace or remove low batteries as soon as possible to prevent corrosion damage to remote control acces sory 15 HAND HELD TRANSMITTER OPERATION Move the side Slide Switch into the ON position tow ards the flat end of the unit Press and hold the control button see Figure 11 on the Hand Held Remote until burner turns on Press and hold the control button agai...

Страница 16: ...nd let cool Remove blockage Blocked burner flame holes will create soot MAIN BURNER BURNER FLAME PATTERN Figure 15 shows the correct burner flame patern Figure 16 shows the incorrect burner flame patern turn Gas Log Set off see Turning OFF the Ap pliance page 15 see Cleaning and Maintenance this page see Troubleshooting page 22 CLEANING AND MAINTENANCE WARNING Turn off Gas Logs and let CAUTION keep...

Страница 17: ... See Fig 18 See Fig 18 Figure 18 Pilot Inlet Air Hole 19 17 ...

Страница 18: ...18 ...

Страница 19: ...19 ...

Страница 20: ... RMH 120 SP051 RMH 120 SP049 9 Orifice Tube Main Burner 1 RMH 120 09003 RMH 120 09003 9 Orifice Tube Main Burner 1 RMH 120 09004 RMH 120 09004 10 Elbow 375 MNPT X 375 Flare 1 RMH 120 00062 RMH 120 00062 11 Adapter 375 MNPT X 5625 Flare 1 RMH 120 00050 RMH 120 00050 12 Adapter 375 FNPT X 5625 Flare 1 FCHD1809021 FCHD1809021 13 Tube Main Gas Supply 1 WIP 120 90414 WIP 120 90414 14A Remote Receiver 1...

Страница 21: ... heater will not produce the specified heat propane LP gs supply may be low You may feel your gas pressure is too low If so contact your local natural or propane LP gas supplier Note Use only original replacement parts This will protect your warranty coverage for parts replaced under warranty TECHNICAL SERVICE You may have further questions about installation opera tion or troubleshooting If so co...

Страница 22: ...n rust or discoloring of any kind use or installation contrary to instructions and applicable building codes including heating the product to temperatures above its rated specifications which can cause considerable warping disassembly including removal of the product from a built in installation damage resulting from accident alteration misuse abuse hostile environments or improper installation rep...

Отзывы: