13
The strange noise is caused by interference. Disconnect the mains power lead from the back of
the base unit, and then wait for 30 seconds before reconnecting it.
There is
'beep' sound while I am on a call.
You may be going out of range of the base unit. Move closer, or your call may be cut off.
Check the Batteries Level symbol on the display. If it is low, recharge the batteries.
The Caller Display feature isn’t working.
You need to subscribe to the Caller Display feature from your service provider.
The caller may have withheld their number, or they may be calling from a network that does
not transmit the Caller ID (for example, it may be an international call).
The handset’s batteries is running low within an hour or two.
Before you used the handset for the first time, you should have left it on the base unit for up to
15 hours to charge the batteries fully.
You may need to replace the batteries.
I cannot transfer a call.
Make sure the other handset is within range of the base unit, and is not busy on a call.
Make sure you are keying in the correct number for the other handset.
No display on LCD screen.
Make sure the batteries have power.
I cannot register handset to base
Make sure the number of handset registered to base is less than 4.
Check that the base unit is not near other electrical equipment, such as TV or computer
Technical Details
Full DECT GAP Compatible system
Standard
: Digital Enhanced Cordless Telecommunications (DECT)
Frequency range
: 1.88 to 1.9 GHz
Channel bandwidth
: 1.728 MHz
Modulation
: GMSK
Operating range
:
Up to 300 m outdoor. Up to 50 m indoor
Operating time
: Standby time of 100 hours, Operating time of 8 hours.
Temperature range
: Operating at 0
0
C to 40
0
C, Storage at -20
0
C to 60
0
C
Electrical power
: Handset- 2x1.2V 550 mAH NiMH rechargeable battery
Base- Input 230 V AC, 50 Hz. Output AC 7.5V, 350mA
Dial Mode
: Pause length: 3 seconds. Signaling type: DTMF (dual-tone
multifrequency) Pulse dialing.
Declaration of conformity
The SD2100 complies with the essential protective requirements and objectives of:
•
EC R& TTE Directive 1999/5/EC
•
EC Low Voltage Directive 73/23/EEC
•
EC EMC Directive 89/336/EEC