 Memory data elimination 

          1) Press the POWER key in measuring mode to turn the power off of DFT. 
          2) Press the POWER key holding the MEMO No. key. 
            (Press the MEMO No. key until the measuring mode comes up.) 
            Eliminates all the data memorized by memory function. 
      (6) Backlight function 
        When it is too dark to see the LCD display, press the LIGHT key. 
        A backlight is lit. (A backlight turns off automatically in 10 seconds.) 
 
   

5.2 Immersion type thermocouple measuring mode  

      (1) Turn the power on by pressing the POWER key. 
      (2) If it is in the measuring mode, change the mode to the immersion type thermocouple measuring 

mode referring to 4.3 Setup section. “EI” is indicated at the right bottom of the display 
if it is in the immersion type thermocouple measuring mode. 
However, even if it is changed to immersion type thermocouple measuring mode, when 0 is set 
in the time setting, the mode is still Peak HOLD measuring mode and “P.HOLD EI” is indicated 
at the right bottom of the display. 

      (3) Temperature measuring starts. 

• When “EI” is indicated at the right bottom of the display

 

When temperature exceeds the value which was preset by timer start temperature setting,   
the timer starts. After it starts, when the time that was preset has passed, the temperature data 
is held and starts blinking. (When Auto-Power-Off is set, at this moment time for Auto-Power-Off 
starts counting. Unless DFT is operated within a preset time, power is automatically turned off.) 
Press the 

 key to cancel the blinking indication. A blinking indication is cancelled and the 

current temperature is indicated. 
However, even if blinking is cancelled, when the indicated temperature is higher than the value 
that was set in the timer start temperature setting, EI function does not work. 
To start EI function again, be sure to let the indicated temperature be -5 (10 ) or lower. 

• When “P.HOLD EI” is indicated at the right bottom of the display. 

This is Peak HOLD (P.HOLD) measuring mode. (When Auto-Power-Off is set, power is  
automatically turned off unless DFT is operated within a preset time.) 
To cancel Peak HOLD (P. HOLD), press

 the 

 key. 

The held data is cleared after pressing the 

 key and the measured value is indicated when 

the 

 key is pressed. 

      (4) Memory function 
        A maximum of 10 (0 to 9) pieces of data can be memorized and be indicated again. 
         Memorization of the indicated data and calling. 
          1) Press the MEMO No. key. 
            When temperature is being measured, memory number “MEMO No. 0”, memory data and the 

data which is being measured are indicated on the display and the mode switches to memory 
mode. 

            Data which is not memorized is represented as “

”. 

          2) Press the key while the data is indicated. 
            The data when 

key was pressed is memorized at the memory number “MEMO No. 0” which 

is currently indicated. 

          3) Next memory number “MEMO No. 1” is indicated by pressing the MEMO No. key again. 

Keep pressing the MEMO No. key until the memory number to call is indicated. 

         Cancellation of the memory mode 
          Press MEMO No. key for 2 seconds or more to cancel the memory mode. 
          The “MEMO No.” is put out and the memory mode is cancelled. 
         Elimination of the memorized data 
          1) Press the POWER key in the measuring mode and the power to DFT is turned OFF. 
          2) Press the POWER key while the MEMO No. key is being pressed. 
            (Press the MEMO No. key until the mode turns to the measuring mode.) 
            All the data that was memorized by memory function is erased. 
      (5) Backlight function 
        When it is too dark to see the LCD display, press the LIGHT key. 
        A backlight is lit. (A backlight is put out in 10 seconds automatically.) 
 
 
      

* Note 

Содержание DFT-700-M

Страница 1: ...gories Warning and Caution Depending on circumstances procedures indicated by Caution may have serious consequences so be sure to follow the directions for usage Procedures which may lead to dangerous conditions and cause death or serious injury if not carried out properly Procedures which may lead to dangerous conditions and cause superficial to medium injury or physical damage or may degrade or ...

Страница 2: ...odel name label is on the back of the case Fig 1 3 1 Do not drop DFT and sensors strike them with hard objects press hard on them as this may lead to the breakdown or malfunction The heat resistance of DFT sensor knob and cable section is low unlike sensor measuring part metal section so use them in a temperature ranging from 0 to 50 Do not use them in or near water which may cause breakdown or ma...

Страница 3: ...ing the MODE key for 1 second turns the measuring mode to the Peak HOLD P HOLD measuring mode and the display indicates P HOLD Pressing the MODE key again for 1 second reverts the controller mode to the measuring mode and P HOLD on the display goes out 12 LIGHT key Pressing the LIGHT key turns on the backlight which goes out automatically after 10 seconds 13 HOLD RST key In the measuring mode the ...

Страница 4: ...the battery case Insert as indicated by 3 and then swing them in 4 Fig 4 1 2 If batteries are inserted correctly DFT 700 is indicated on the LCD display for 5 seconds and then returns to the power switches OFF When removing the batteries After making sure that power is OFF push side of the batteries up in the direction indicated by 5 then swing them in the direction indicated by 6 and remove them ...

Страница 5: ...ermocouple can be used or not with the or key Not indicated when RTD Pt100 or Thermo hygro sensor is selected in the Sensor selection Selection item Normal measuring mode Immersion type thermocouple measuring mode Factory adjusted normal measuring mode Selects the Auto Power Off time with the or key Selection item Not used 10 min 30 min 60 min Factory adjusted 10 minutes Sets the measuring time af...

Страница 6: ... 700 P is measuring temperature and humidity P HOLD is indicated on the display and the maximum value of humidity data currently indicated and temperature data when humidity data is maximum are held Temperature is indicated on the Data display and humidity is indicated on the PV display When this function is selected the indicated values are not renewed as long as temperature and humidity do not e...

Страница 7: ...lue that was set in the timer start temperature setting EI function does not work To start EI function again be sure to let the indicated temperature be 5 10 or lower When P HOLD EI is indicated at the right bottom of the display This is Peak HOLD P HOLD measuring mode When Auto Power Off is set power is automatically turned off unless DFT is operated within a preset time To cancel Peak HOLD P HOL...

Страница 8: ...on turns from 0 1 to 1 Battery life warning indication When the battery voltage lowers the battery life warning indication blinks and indicates that it is time to change batteries Input burnout indication Overscale In the case of thermocouple and RTD input blinks on the PV display if the sensor is burnt out or the value exceeds the rated scale maximum value Immersion type thermocouple measuring mo...

Страница 9: ...CE 706 For measuring temperature of liquid and interior 400 PCE 707 For measuring general surface temperature 400 PCE 707L For measuring general surface temperature 400 PCE H7 Exclusive use tip for PCE 707 707L for exchange 400 PCE 709 For measuring temperature of liquid and interior 400 PCE 700 M For measuring surface temperature of mold etc Magnet type 300 7 2 RTD Pt100 Model Drawing Main object...

Страница 10: ... period 0 4 seconds Standard function Automatic cold junction temperature compensation Only thermocouple input Automatic POWER OFF Auto range EI Immersion type thermocouple measuring mode Decimal point indication switch Battery life warning indication Input burnout Overscale Underscale Temperature unit selection Multi range input Memory backup Memory data clearing Dust proof Drip proof IP65 Supply...

Страница 11: ...Cancel the Data HOLD D HOLD or Peak HOLD P HOLD Humidity sensor HD S of Thermo hygro sensor THD 700 P is out of order Replace the humidity sensor with a new one Indication of the PV display or Data display is abnormal or unstable Sensor input designation is incorrect Set the correct sensor input unit is incorrect Set the correct temperature unit AC is leaking from the measured object to thermocoup...

Страница 12: ... sure to turn the power OFF of DFT 700 M when DFT 700 thermo hygro sensor hereinafter THD 700 P is attached or detached from DFT 700 M Do not attach or detach THD 700 P in wet place or with wet hands because it may cause electric shock Warning The maximum temperature written in the table is the limit temperature of the measuring part Use such as grip cord etc in an ambient temperature 0 to 60 exce...

Страница 13: ...rica Ltd Reg Office Mail Address URL Toll Free 25 Whitefriars Drive Toronto Ontario Canada M3A 2L2 25 Whitefriars Drive Toronto Ontario Canada M3A 2L2 http www shinkona com 1 866 4SHINKO Tel Fax 416 444 0817 416 444 2361 ...

Отзывы: