YQE8-J0092E
9
(8)Cleaning Ejection Roller
①
Remove Side Cover L, Side Cover R, Front Cover, and cleaning roller (ejection side).
②
Remove 2 screws (M3x6) which hold PCB HSSV7-LCDSOSA-F ASSY and remove the PCB (removing
wire harness is not required).
③
Remove 2 screws (M3x6) which hold the Paper Cutter Unit, then remove the Paper Cutter Unit, and clean
the Ejection Roller.
(9)Separation Plate and Ribbon Sensor Reflection Shield
Clean the Separation Plate and Ribbon Sensor Reflection Shield with the upper unit opened.
Separation Plate
Ribbon Sensor Reflection Shield
Warning: Do not touch the blade of the cutter unit in order to avoid injury.
Screw
HSSV7-LCDSOSA-F ASSY
Paper Cutter Unit
Screw