11(65)
1.3.2 Pump Performance
Picture 1-1
:
Pump Performance
1.3.3 Reference Formula of Mould Controllers Model Selection
Heater Power (kW) = mould weight (kg)
×
mould specific heat (kcal/kg
)
×
℃
temperature difference between mould and environment (
)
×
safety coefficient
℃
/ heating duration / 860
Note: safety coefficient can select a value from 1.3 to 1.5.
Flow Rate (L/min) = heater power (kw)
×
860 / [heating medium specific
(kcal/kg
)
×
heating medium density (kg/L)
×
in/outlet temperature di
℃
fference
(
)
×
time (60)]
℃
Note: Water specific heat =1kcal/kg
℃
Heating medium oil specific heat =0.49kcal/kg
℃
Water density =1kg/L
Heating medium oil density =0.842kg/L
Содержание STM-1220-PW