35(40)
6.2.3 Parameter List
Code
Status
Default
Value
Adjusting
Range
Mode
F2
Necessary spray washing times every
several times for operation
3times
1~10 times
C2
F3
Necessary cleaning times for reverse
running every several times of operation
3 times
1~10 times
C3
F4
Motor reverse running time
10sec
5~30 sec
C3
F5
Alarm detecting time
20 sec
10~40 sec
C1,C2,C3,C4
F6
Awaits motor to stop time
30 sec
30~99 sec
C3
F7
Purge times
2 times
1~5 times
C2
F8
Loading latency time
0
0~99 times
C1,C2,C3,C4
6.2.4 Other Settings
1. Any setting before power on will be saved automatically and back to shut off
state after 5 second of no operation.
2. Any setting after power on will be saved automatically and back to standby
state after 5 second of no operation.
3. No material shortage signal is being detected even after all action is over,
then if press
key for 3 second
,
motor will perform reverse running action,
when release the
keys to stop motor and await the motor stop count
down and back to standby state to detect material shortage signal. (The
function only suitable for SAL-430/460 model)
4. Function of the jumper: functions of C1, C3 and C4 will be activated when
jumping out which is applicable to SAL-700G / 800G / 430 / 460. When
disconnected, only functions of C1, C2 and C4 are available which can be
used for SAL-700G / 800G / 330 / 360.
Содержание SAL-330
Страница 1: ...SAL 330 360 Self contained Hopper Loader Date Jan 2016 Version Ver B ...
Страница 2: ......
Страница 6: ...6 40 ...
Страница 21: ...21 40 4 Electrical Circuit Diagram 4 1 Electrical Diagram Picture 4 1 Electrical diagram ...
Страница 31: ...31 40 6 2 Function Setup 6 2 1 Setup ...
Страница 33: ...33 40 ...
Страница 34: ...34 40 ...