OFS-80
Optical Fiber Fusion Splicer User’s Manual
Shineway Technologies, Inc.
- 23 -
Each tube-heating mode is optimized for a type of protection sleeve. These modes can be
found in database area for reference. Copy the appropriate one and paste it to the
user-programmable area. The operator can edit the user-programmable modes.
(1) Select Heater Mode
In 1.“Splice Mode Menu”, press
or
button to select “Select Heater Mode”, press
button to enter as shown below:
Select the heater mode most suitable for the protection sleeve to be used.
Press
or
button to select a heater mode, press
button to confirm.
(2) Edit Heater Mode
Tube-heating conditions stored in heater mode can be edited or changed.
Editable parameters include: Heat Time, Heat Temp (heating temperature) and etc. Heat
Time will automatically adjust according to atmospheric conditions e.g: ambient
temperature. The real Heat Time may vary from set Heat Time.
Sets heating temperature. Fiber coating may melt if Heat Temp is over 190
℃
Sets Finish Temp (Finish Temperature). When heater approaches this temperature the
buzzer beeps announcing the sleeve is cooled down and is ready to be taken out of the
heater.
In “Select Heater Menu”, press
button to enter “Heater Mode Edit” menu as shown
1
2
3
4
:
Exit
:
Select
Splice Memory
Splice Option
Select Splice Mode
+
Splice Mode Menu
Select Heater Mode
Select Heater Mode
1 60mm
60mm
2 40mm
40mm
3 35mm
35mm
4 25mm
25mm
:
Exit
:
Select
:
Edit Mode
+