background image

 

OFS-80

 

Optical Fiber Fusion Splicer User’s Manual 

 

Shineway Technologies, Inc.                  

 

- 22 -

 

 

splice mode as shown above: 

 

Press 

  or

button  to  select  the  parameter  to  be  modified,  press 

 

  button  to 

enter parameter setting. 

Press 

  or

  button to modify parameter, press 

 

  button to confirm. 

 

In AUTO mode, certain parameters cannot be changed. 

Parameter 

Description 

Fiber Type 

List of splice modes stored in database is displayed. A selected splice   

mode stored in the database area is copied to a selected splice mode in   

the user-programmable area. 

Mode Title1 

Title for a splice mode expressed in up to seven characters. 

Mode Title2 

Detail explanation for a splice mode expressed in up to 15 characters.     

Title2 is displayed at the [Splice Mode Select] menu. 

Cleave Limit 

Set cleave limit. An error message is displayed if  the cleave angle of 

either the left or right fiber ends exceeds the selected threshold. 

Loss Limit 

An error message is displayed if the estimated splice loss exceeds   

selected threshold (loss limit). 

Arc Power 

In SM/DS/MM/NZ/AUTO modes, the Arc Power is fixed at 40 bits. 

Arc Time 

Arc Time is fixed at 1500 ms for SM and DS modes, 2000 ms for NZ   

mode, and 3000 ms for MM mode. This is automatically set depending 

on the fiber type when AUTO mode is selected. 

Cleaning Arc 

A cleaning arc burns out micro dust on the surface of the fiber with an   

arc discharge for a short period of time. The duration of the cleaning   

arc can be changed by this parameter. 

Rearc Time 

Splice loss may be improved by an additional “rearc” discharge in   

some cases. The duration of this additional arc can be changed by this 

parameter. 

 

4.1.2 Heater Mode 

There are 20 user-programmable heating modes. Select one best suitable for the protection 

sleeve used. 

 

Содержание OFS-80

Страница 1: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc...

Страница 2: ...OFS 80 Optical Fiber Fusion Splicer...

Страница 3: ...but not limited to the implied warranties of merchantability and fitness for a particular purpose Shineway Technologies Inc shall not be liable for errors contained herein or for incidental or conseq...

Страница 4: ...meters For more details please refer to the specifications tables Before Applying Power Verify that the product is set to match the available line voltage the correct fuse is installed and all safety...

Страница 5: ...instructions Stop using it when it malfunctions and ask our service centers for repair as soon as possible Read this instruction manual carefully before operating this machine Disconnect the AC power...

Страница 6: ...eplacing electrodes Safety glasses should always be worn during fiber preparation and splicing operation Fiber fragments can be extremely dangerous if it comes into contact with the eye skin or is ing...

Страница 7: ...d and AC plugs with wet hands This may result in electric shock Do not operate splicer near hot objects in hot temperature environments in dusty humid atmospheres or when water condensation is present...

Страница 8: ...icer from damage moisture vibration and shock during storage and transportation Follow the below listed instructions for handling electrodes Use only specified electrodes Set the new electrodes in the...

Страница 9: ...1 2 Turning Splicer ON 15 3 1 3 LCD Brightness Adjustment 15 3 2 Fiber Preparation 16 3 2 1 Placing Protection Sleeve over Fiber 16 3 2 2 Stripping and Cleaning Fiber 16 3 2 3 Fiber Cleaving 17 3 2 4...

Страница 10: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc x 6 3 Warranty Registration 29 6 4 Returning Instruments 29 6 5 Contacting Customer Service 30...

Страница 11: ...c immediately Retain the original packing materials in case reshipment becomes necessary 1 2 Unpacking and Inspection This instrument has been carefully packed in accordance with standard shipping pro...

Страница 12: ...n size and light in weight making it suitable for any operating environment It is easy to operate and it splices fast while maintaining low splice loss In order to achieve the splicer s full capabilit...

Страница 13: ...OFS 80 Optical Fiber Fusion Splicer User s Manual Shineway Technologies Inc 13 V groove Guide Groove Electrode Cover Wind Protector Mirror Fiber Clamp Sheath Clamp Electrode Cover Sheath Clamp...

Страница 14: ...ace Detaching power supply unit Turn off the splicer Push the release button located on the side of the splicer body and remove the power supply out of the splice body Two ways to check remaining batt...

Страница 15: ...played after all the motors reset to their initial positions The power source type is automatically identified If the battery is used the remaining battery capacity is displayed 3 1 3 LCD Brightness A...

Страница 16: ...or lint free tissue Dust particulates can enter inside the protection sleeve and might result in a future fiber break or attenuation increase Make sure fiber is passed into the protection sleeve When...

Страница 17: ...ouch anything 3 2 4 Loading Fiber to Splicer Open wind protector and sheath clamps Place prepared fiber onto v groove so that the fiber tip is located between the v groove edge and tip of electrode Ho...

Страница 18: ...pping is detected the buzzer will sound and an error message warns the operator The splicing procedure pauses If no error message is displayed the below stated end face conditions are used for visual...

Страница 19: ...e for details Splice loss may be improved in some cases by additional arc discharges Press ARC button for an additional arc discharge re arc Splice loss estimate and splice check are performed again S...

Страница 20: ...leeve to verify no bubbles or debris dust is present in the sleeve 4 Menu Operation Press MENU button to enter splicer menu there are four main menus 1 Splice Mode Menu 2 Management Menu 3 Maintenance...

Страница 21: ...mmended for splcing in most cases in which the splicer will automacially adjust splice parameters according to fiber type 2 Edit Splice Mode Splicing parameters in each splice mode can be modified In...

Страница 22: ...An error message is displayed if the cleave angle of either the left or right fiber ends exceeds the selected threshold Loss Limit An error message is displayed if the estimated splice loss exceeds s...

Страница 23: ...Tube heating conditions stored in heater mode can be edited or changed Editable parameters include Heat Time Heat Temp heating temperature and etc Heat Time will automatically adjust according to atmo...

Страница 24: ...2 Heat Temp 60mm 60mm 36 sec 180 Finish Temp 90 1 Exit Select LR Heat Power Center Heat Power Heater Control Heater Mode Edit Long Cool Time 150 bit 15 sec 2 150 bit Heat Time Center side 1 2 3 4 Exit...

Страница 25: ...s up to 5 000 splicing results In Splice Memory menu operator can review saved results or delete saved results 4 2 Management Menu This menu is used to change language and power save settings Press or...

Страница 26: ...any key to turn back on the LCD monitor Splicer can also automatically turn off after certain period of time without operation 0 20 minutes adjustable 4 3 Maintenance Menu OFS 80 has the ability to p...

Страница 27: ...r cleaver is well conditioned Core step Dust on v groove or fiber clamp chip Clean v groove and fiber clamp chip Core Curve Bad fiber end face quality Check if fiber cleaver is well conditioned Prefus...

Страница 28: ...ber stuffing too small Perform Motor Calibration Prefuse power too high or prefuse time too long Decrease Prefuse Power and or Prefuse Time Fat Fiber stuffing too much Decrease Overlap and perform Mot...

Страница 29: ...e parts e g electrodes Shineway Technologies Inc reserves the right to make changes to any of its products at any time without having to replace or change previously purchased units 6 3 Warranty Regis...

Страница 30: ...ntact phone number email address and problem description Be sure to seal the packing box with exclusive tape Be sure to ship to your representative or the agent of the Company in a reliable way 6 5 Co...