4
PRECAUTIONS
Do not paint radiant screen, control panel or top canopy
reflector.
Young children should be carefully supervised when they
are in the area of the heater.
Clothing or other flammable material should not be hung
from the heater, or placed on or near the heater.
Keep the appliance area clear of combustible materials
such as gasoline and other flammable vapors and liquids.
Do not obstruct the flow of combustion and ventilation air.
NOTE: PLEASE READ THE FOLLOWING SAFETY RULES
All leak tests should be done with a soapy solution. NEVER
USE AN OPEN FLAME TO CHECK FOR LEAKS.
The natural gas hose assembly shall be located out of
pathways where people may trip over it or in areas
where the hose will not be subject to accidental damage.
Children and adults should be aware of the hazards of high
surface temperature and shall stay away to avoid burns or
clothing ignition.
Do not use the heater in an explosive atmosphere.
Keep the heater away from areas where gasoline or other
flammable liquids or vapors are stored.
Do not clean the heater with cleaners that are combustible
or corrosive.
The appliance shall not be used in basements or below
ground level.
It must always be placed on a solid and level surface.
Read the instructions before use.
This appliance must be installed in
accordance with such regulations as
are in force.
This appliance must only be used outdoors.
Using this product in an enclosed area may cause
injury, death or property damage.
WARNING
DISCONNECT
Natural Gas before moving the heater.
Do not attempt to alter unit in any manner.
EXAMPLE
: using the heater without the top canopy
reflector or radiant screen.
Do not shorten the burner post assembly.
Always assure there is ample fresh air ventilation.
For outdoor use ONLY.
The installation of fixed appliances shall only be carried out
by competent persons and be in accordance with local codes
or in the absence of local codes, with the national fuel gas code
ANSI Z
223.1 in the USA or the CSA B149.1 natural gas and
propane installation code in Canada. The manifold pressure and
minimum inlet supply pressure is 7.0 inches water column.
The maximum supply pressure is 10.5 inches water column.
Prior to use, check for damaged parts such as gas hoses,
natural gas pipe, pilot or burner.
The appliance and its individual shut off valve must be
disconnected from the gas supply piping system during any
pressure testing of that system at test pressures in excess
of 0.5 PSIG (3.5 KPA).
The appliance must be isolated from the gas supply piping
system by closing its individual manual shut off valve during
any pressure testing of the gas supply piping system at test
pressures equal to or less than 0.5 PSIG (3.5 KPA).
Warning:
This appliance requires a gas hose and natural
gas pipe, check with your gas supplier and or product supplier.
Regularly check the gas hose and natural gas pipe,
if necessary, replace the gas hose or natural gas pipe.
At least once a year
,
the unit should be inspected
for the
presence of spiders, spider webs or other insects. Check the
heater immediately if any of the following exist:
1. The smell of gas in conjunction with extreme yellow
colored tips of the burner flames.
2. The heater does not reach temperature.
3. The burner makes popping noise during use (a slight
popping noise is normal when the burner is extinguished
after using).
The natural gas should be turned off when the heater is
not in use.
Installation and repair should be done by a qualified
service person. The heater should be inspected before
use and cleaning may be required at least once a year, or as
necessary. It is imperative that control compartment, burner
and circulating air passageways of the heater be kept clean.