10
ASSEMBLY
NOTE: Assembly of this heater requires
basic mechanical skills. Proper assembly
is the responsibility of the installer.
Step 9 ----Connect Gas Hose to Natural Gas
Step 9
Attach Gas hose to Natural Gas with
Quick disconnect device.
Step 10
Step 10 ----Check for leak
Your Patio Heater has been checked at all
factory connections for leaks,To check the
Connection of the gas hose/natural gas pipe.
1)Make leak solution by mixing 1 part liquid
dish soap and 3 parts water.
2)Spoon several drops(or use squirt bottle)
of the solution onto the gas hose/gas pipe
connection.
3)Open the control panel access cover.
Squirt all the connections inside,including
the hose connection inside the post.
4)Inspect the connections and look for bubbles.
5)If no bubbles appear,the connection is safe.
6)If bubble appear,there is leak,loosen and
re-tighten this connection.
16