Symptom
Possible Causes
Remedy
Lamp does not light up
Output switch is "OFF"
Turn the Output switch to "ON"
Lamp was turned on again right after
being turned off
Wait approximately 15 minutes
after turning off the lamp for it to
cool before turning it on again
Ballast is not compatible with the
lamp
Replace with a compatible lamp
Lamp is loose
Securely tighten the lamp
Lamp deterioration
Replace the lamp
Lamp is dark
Lamp deterioration
Replace the lamp
Balloon fabric is dirty
Wipe away any dirt or grime
(cannot be scrubbed)
Replace the balloon fabric
Balloon fabric does not
inflate
Large tear in the balloon fabric
Replace the balloon fabric
Fan does not operate
Repair
Balloon fabric is wet
Dry the balloon fabric before
using
Balloon fabric only inflates
slightly
Zipper is open
Close the zipper
Velcro has become detached
Re-affix the Velcro
Filter is clogged
Clean the filter
Tear in the balloon fabric
Repair
Deterioration of balloon fabric
Replace the balloon fabric
Lamp turns off with the
balloon fabric inflated
Lamp service life
Replace the lamp
Lamp goes off with the
balloon fabric deflated
Fan stops and overheat prevention
device operates
Repair or replace the fan
Mast does not go up
Mast does not easily slide
Apply grease to moving parts
Poor pulley rotation
Apply grease to pulleys
Foreign material is caught in the
mast
Repair
Mast comes down
Winch brake malfunction
Repair
Mast does not go down
Mast does not easily slide
Apply grease to moving parts
Fall prevention device has a
malfunction
Repair (Slowly lower the mast
while reeling in the winch and
pressing the mast down)
Foreign material is caught in the
mast
Repair