(2) Cleaning Dirt from the Balloon Fabric 

Wipe away any dirt or grime by using a cloth to which a neutral detergent has been applied. 

 
<Note> 

 Do not use any solvents such as alcohol or gasoline to clean. 

 Do not clean by scrubbing or using a washing machine. Doing so can damage the fabric 

coating. 

 
(3) Repairing the Balloon Fabric 

Affix a repair patch (adhesive on backside) to the surface of the balloon fabric. Clean away 
any  dust  or  oil  from  the  patch  application  area  before  affixing  and  press  strongly  on  the 
patch after affixing. 

 
(4) Adjusting the Brakes 
 

WARNING: TIPPING OVER 

 As  the  tower  light  brake  function  cannot  be  used  when  adjusting  the  brake, 

always  be  sure  to  position  the  tower  light  on  a  level  surface  with  a  solid 
foundation,  place  wheel  chocks  and  lower  the  mast  until  it  is  at  the  lowest 
position. 

 
 

If  the  brake  effectiveness  seems weak  even  though  tire  pressure  is  between  196  to  245 
kPa (2.0 to 2.5 kgf/cm

2

), perform the following procedures to correct the angle of the brake 

stopper. 
 

Move this tower light to a level location and place wheel chocks. 

 

Release the wheel brakes. (Refer to "5-2. Applying the Wheel Brakes".) 

 

Loosen the nuts of the right and left brake rods. 

 
 
 
 
 
 
 
 
 

Set the brake stopper angle at a position that is 
inclined  approximately  10°  to  the  wheel  side 
from directly vertical. 

 

Tighten the nuts of the right and left brake rods 
to secure the stoppers. 
Further increase the stopper angle if the brakes 
are not sufficiently effective. 

 
 

(5) Applying Grease to Pulleys 

 

Remove  the  two  bolts  and  bolt/nut  assembly 
securing the pulley cover. 

 
 
 
 
 
 
 
 
 

Brake Rod 

Tighten 

Loosen 

Detail of Brake 

Approx. 10°

Bolt/Nut 

Bolts (2) 

Pulley Cover

Mast 1st Stage

 

 

 

Brake 
(Stopper)

Содержание SBL133IDG

Страница 1: ...L Balloon Tower Light SBL133IDG CAUTION Do not operate the Tower Light or any other appliance before you have read and understood the instructions for use and keep near for ready use SBL133IDG AF S1W...

Страница 2: ......

Страница 3: ...or consulting at any time Order another copy from the authorized distributor where this tower light was purchased if this manual becomes lost dirty or damaged Consult with the authorized distributor w...

Страница 4: ...he Mast 9 6 Assembly at Purchase 10 6 1 Removing the Lamp Fitting Cover 10 6 2 Installing the Balloon Fabric 11 7 Operating Procedures Tower Light 12 7 1 Turning on the Lamp 12 7 2 Turning off the Lam...

Страница 5: ...e rope from becoming loose As the tower light brake function cannot be used when adjusting the brake always be sure to position the tower light on a level surface with a solid foundation place wheel c...

Страница 6: ...Replace warning and caution labels with new ones if they become damaged and difficult to read Order labels by using the part number indicated in parenthesis below 1 DANGER INJURY TIPPING OVER Part no...

Страница 7: ...Dimension Height when in use mm 5 020 2 470 When stored Total Length mm 1 280 Total Width mm 790 Outer Tire Width mm 790 Total Height mm 1 820 Dry Weight kg 135 Equipped Generator Model IDG3100M Gene...

Страница 8: ...Tilt Handle Pulley Cover Lifting Lug Generator Wheel Tire Brake Stopper Storage Hook for Lamp Fitting Cover Lamp Holder Lamp Lamp Guard Lamp Fitting Base Lamp Fitting Lever Rotation Handle Dolly Hand...

Страница 9: ...using the dolly handle can result in deformation and damage 5 2 Applying the Wheel Brakes Note If the brake force is weak adjust the wheel air pressure and brake stopper angle Refer to 12 Inspection M...

Страница 10: ...be locked at a height within a range of approximately 100 mm above and below the level position On an inclined surface be careful as the outrigger locked height is different by setting blocks under t...

Страница 11: ...otation handle again by using both hands and securely fix the lamp fitting 2 Adjusting the Lamp Fitting Tilt Angle Tilt the lamp fitting as necessary according to the application Place the lamp fittin...

Страница 12: ...difficult when nearing the highest mast position Do not force the mast beyond that position The highest position is where you can see the arrow label Forcibly turning the winch can result in malfunct...

Страница 13: ...it Refer to 5 4 Using the Lamp Fitting Remove the lamp fitting cover Removing the Lamp Fitting Cover 1Untie the knot of the cord slide the cord stopper and make the opening larger Insert the lamp fitt...

Страница 14: ...ring the lamp guard and affix the Velcro tabs of the lamp fitting base and balloon fabric At this time position the pins located around the lamp fitting base so that they fit into the balloon fabric g...

Страница 15: ...ot work for an extended period of time near the lamp and do not look directly into the lamp CAUTION ELECTRIC SHOCK Do not sprinkle water on the equipment and do not use where exposed to rain Note Usin...

Страница 16: ...e Mast 7 2 Turning off the Lamp Lower the mast Refer to 5 5 Lifting Lowering the Mast Turn the generator Output switch to OFF to turn off the lamp Note Do not turn off the lamp by removing the power p...

Страница 17: ...mp could result in lamp damage To lift this tower light place the lamp fitting so that it is horizontal and rotate it so that the lamp fitting is facing the opposite direction of the lifting lug The l...

Страница 18: ...forks aligned with the fork position labels and scoop up the equipment Note Always be sure to insert the forks so that they are inserted into the indicated fork guides Failure to insert the forks int...

Страница 19: ...BD 1 000 W metal halide lamp manufactured by Iwasaki Electric rated voltage of 250 V for the lamp When disposing of a replaced lamp do so in a manner that is in compliance with laws related to industr...

Страница 20: ...ting base but leave the tilt part remaining Remove the nut and bolt supporting the lamp fitting so that it remains well balanced and pull it off of the shaft 11 Generator Loading Unloading Procedures...

Страница 21: ...g and generator and push the lifting lug to the mast side Remove the eight bolts securing the metal holders saddles of the generator wheels casters Unload the generator from the dolly 4 5 6 Bolt Nut L...

Страница 22: ...e with laws related to industrial waste Contact the authorized distributor where this tower light was purchased if you have any inquiries regarding proper disposal No Location Check for Pre Operation...

Страница 23: ...r Lever Movement Apply Moly HD Grease 22 Handle Fixing Bolts Looseness Tighten 23 Lifting Lug Fixing Bolts Looseness Tighten 24 Generator Fixing Bolts Looseness Tighten 25 Front Wheel Steering Shaft M...

Страница 24: ...n place wheel chocks and lower the mast until it is at the lowest position If the brake effectiveness seems weak even though tire pressure is between 196 to 245 kPa 2 0 to 2 5 kgf cm2 perform the foll...

Страница 25: ...d and third stages one each on the right and left Accordingly lower the mast to the lowest position and apply spray grease from above 6 Providing Grease to the Front Wheel Steering Shaft Use a grease...

Страница 26: ...is not only to keep the balloon fabric clean but also to prevent the service life of the balloon fabric from being reduced by the wind and ultra violet rays If not using this tower light for two month...

Страница 27: ...is dark Lamp deterioration Replace the lamp Balloon fabric is dirty Wipe away any dirt or grime cannot be scrubbed Replace the balloon fabric Balloon fabric does not inflate Large tear in the balloon...

Страница 28: ...25 2017...

Отзывы: