30
The circuit breakers react on the AC power supply circuit only. In the simultaneous use of welding and
generating, there may be happen overload to the engine. Refer to the following table and limit AC power use.
Limitation of AC Power Supply in the simultaneous use of welding and generating (60Hz)
DGW310DMC
Welding Output
AC Power Output
Rod/Current
Select
3-P Output (PF 0.8)
1-P Output
φ
2.0mm/60A
Dual
9.3kVA
7.4kVA
φ
2.6mm/120A
Dual
7.2kVA
5.7kVA
φ
3.2mm/140A
Dual
6.4kVA
5.1kVA
φ
4.0mm/170A
Dual
5.2kVA
4.1kVA
φ
5.0mm/240A
Single
2.0kVA
1.6kVA
φ
6.0mm/300A
Single
0kVA
0kVA
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
DGW310MC
Welding Output
AC Power Output
Rod/Current
Select
3-P Output
1-P Output
φ
2.0mm/60A
Regular
9.3kVA
7.4kVA
φ
2.6mm/120A
Regular
7.2kVA
5.7kVA
φ
3.2mm/140A
Regular
6.4kVA
5.1kVA
φ
4.0mm/170A
Regular
5.2kVA
4.1kVA
φ
5.0mm/240A
Regular
2.0kVA
1.6kVA
φ
6.0mm/300A
Regular
0kVA
0kVA
The 1-P figure shown is the total output of 1-P 100/110V and 200/220V.
<
<
<
<
Caution
>
>
>
>
●
Simultaneous use of Welding and AC Power is NOT available.
●
Avoid simultaneous use in the case high welding quality is required.
10. Simultaneous use of Generating and Welding