![Shindaiwa DGW310DMC Скачать руководство пользователя страница 27](http://html1.mh-extra.com/html/shindaiwa/dgw310dmc/dgw310dmc_owners-manual_1257728027.webp)
25
Welding Current
at the dial position (A)
Position
Freq
MIN
1
2
3
4
5
MAX
ECO
30
45
70
95
120
145
160
50Hz
70
90
135
175
215
260
280
1 Person
Single
60Hz
85
110
155
200
245
290
310
50Hz
35
45
70
95
115
140
150
2 Persons
Dual
60Hz
45
55
80
105
125
150
160
The values are for reference only. The length or the ambient temperature each affects the value.
When the remote control box is used, the value may change to some degree.
(2) DGW310MC
The current adjustable range by the dial changes at the output selector switch position.
1 Turn the selector switch properly according to operation.
2 Adjust the voltage by the current adjustable dial. Refer to
the following chart next.
Welding Current at the dial position (A)
Position
Freq
MIN
1
2
3
4
5
MAX
ECO
30
45
70
95
120
145
160
50Hz
35
60
110
160
205
255
280
Regular
60Hz
45
70
125
180
230
285
310
The values are for reference only. The length or the ambient temperature each affects the value.
When the remote control box is used, the value may change to some degree.
Current
Dial
Selector
Switch
Output
Terminal