21
7. Keep the engine idle for about 5 minutes.
■
Restarting after stopping due to fuel shortage
This equipment is incorporated in automatic vacuuming air feature. Therefore, even though the engine
stops due to fuel run out, you can restart the engine easily by the following steps.
1. Turn the breakers to
『
OFF
』
2. Turn the starter switch to
『
STOP
』
.
3. Fill the fuel.
4. Turn the slow-down switch to
『
ON
』
.
5. Turn the starter switch to
『
START
』
and drive the starter motor for about 10 seconds.
6. Release the starter switch, promptly as the engine started.
7. Wait for about 1 minute to vacuum the air out. The engine peed becomes stable when the air is
extracted.
<
<
<
<
Caution
>
>
>
>
●
Never turn the engine NORMAL speed or connected the loads until the air is extracted completely (until
the engine becomes stable).
Breaker
Slow-down switch
Starter
Fuel lever
Close
Open