- 12 -
5. Equipment
5-1. Idle Control
The equipment includes an idle control function.
You can use the idle control switch to select an
engine speed setting of "ECO", "AUTO" or "HIGH".
(1)
ECO Drive
The equipment includes an eco drive function in
order to reduce noise, save fuel, and reduce
exhaust gas emission.
When the idle control switch is set to "ECO" and only welding is being performed, the
engine operates at an optimal speed corresponding to the weld output and it
automatically returns to low speed when welding is stopped.
<Note>
If using as an AC power source during eco drive (including when welding and using
as an AC power source at the same time), the engine operates at high speed.
Set the idle control switch to "AUTO" or "HIGH" if welding or using as an AC power
source in an intermittent manner.
Set the idle control switch to "HIGH" if using a high capacity motor, precision
instruments or AC load with an attached magnetic switch.
Set the idle control switch to "HIGH" if using as an AC power source of a device of
0.5A or less because the engine might not reach a high speed as speed control does
not operate at that level.
(2)
Auto Idle
The equipment includes an auto idle function in order to reduce noise, save fuel, and
reduce exhaust gas emission.
You can set the idle control switch to "AUTO" so that the engine operates at low speed
when not welding or using the equipment as a power source.
When you start to weld or use as an AC power source, the engine automatically
increases to high speed. When in a no-load condition, the engine automatically returns
to low speed after approximately 8 seconds of high-speed operation.
<Note>
Set the idle control switch to "HIGH" if using a high capacity motor, precision
instruments or AC load with an attached magnetic switch.
Set the idle control switch to "HIGH" if using as an AC power source of a device of
0.5A or less because the engine might not reach a high speed as speed control does
not operate at that level.
(3)
High Idle
You can set the idle control switch to "HIGH" to maintain the engine constantly at high
speed.
5-2. Display
The equipment includes a digital display that displays the AC Voltage, Hours Worked
and Speed successively by changing the display select switch.
<Note>
During operation, the AC Voltage always displays the three phase 415V output
voltage regardless of whether the breaker is set to "ON" or "OFF".
Idle Control
Switch
Содержание DGW300MS/UKV
Страница 2: ......
Страница 11: ... 6 LABEL REPRODUCTION X505 011481 X505 011470 X564 000640 X564 000630 X505 006410 ...
Страница 12: ... 7 X505 000240 X505 004890 X505 011490 X505 006430 M707 000260 M708 000890 ...
Страница 39: ... 34 15 Engine Wiring Diagram ...
Страница 40: ... 35 16 Generator Wiring Diagram ...
Страница 41: ... 36 MEMO ...
Страница 42: ... 37 MEMO ...
Страница 43: ... 38 ...
Страница 44: ... 39 2021 ...