3 Low evaporative fuel tanks DO NOT require regular maintenance to
maintain emission integrity.
* Replacement is recommended based on the finding of damage or wear
during inspection.
Air Filter
Level 1
Parts Required: Tune Up Kit.
1.
Close choke (COLD START position). This prevents dirt from entering
the carburetor throat when the air filter is removed. Brush accumulated
dirt from air cleaner area.
2.
Remove air filter cover. Brush dirt from inside cover.
Assure throttle wire retaining clip
(A) remains in place as shown
when removing or installing air
filter cover.
3.
Remove foam pre-filter (B) and
air filter (C) and clean as
indicated below:
4.
Foam Pre-filter.
• Clean foam filter in water/
detergent solution and rinse
with clean water.
• Wrap the filter in a clean, dry cloth and squeeze (do not wring) dry.
Allow to dry completely before reuse. Do not oil.
Air Filter
• Lightly brush debris from filter. Replace filter if it is damaged, fuel
soaked, very dirty, or the rubber sealing edges are deformed.
5.
Assemble components in reverse order.
A
B