Items configurable in E-TUBE PROJECT
Display settings
Display time setting
Sets the time until the display turns off when the display
monitor is left unattended.
Switch function setting
Modify the shift switch function settings.
Shift mode setting
Modify the shift mode (synchronized shift) settings.
Multi shift mode setting
Multi-shifting mode ON/OFF
Select whether or not to use multi-shifting.
Gear-shifting interval
Sets the gear-shifting interval for multi-shifting.
Gear number limit
Sets the limit on the number of gears shifted when the
shift switch is pressed and held.
System pairing settings
Performs system pairing (wireless) by reading a QR code
or entering a serial code.
Shift mode setting (synchronized shift)
The shift mode can be set in E-TUBE PROJECT to maintain the ideal front and rear gear positions by
synchronizing the shifting between the front and rear derailleurs.
Semi-synchronized shift
The rear derailleur automatically shifts gears in synchronization with front derailleur gear shifting. The rear
derailleur can be set to automatically shift from 0 to 4 gears. 2 gear positions is the default. The options for the
number of automatic shifts may vary depending on the combination of cassette and chainrings used.
When shifting from the largest chainring to the smallest chainring
The rear derailleur shifts from 0 to 4 gears outward. 2 gear positions is the default.
Up to two shift modes can be set in E-TUBE PROJECT. For the setting procedure, refer to the
.
The shift mode can be switched by double clicking the function button on the rear derailleur. For details, refer
to “
.”
Connection and communication with devices
Items configurable in E-TUBE PROJECT
38