CHARGING THE BATTERY
When charging is not possible
Built-in type (SM-BCR2 / SM-BTR2, BT-DN110 / BT-DN110-A)
1
Make sure that only one unit of SM-BCR2 is connected to a PC.
2
If the ERROR indicator blinks
(A)
If the ERROR indicator blinks, the
ambient temperature during charging
may fall outside the operating
temperature limits.
Check that the temperature is
appropriate.
(A)
ERROR indicator
If the CHARGE indicator blinks
(A)
If the CHARGE indicator blinks, refer to
the following.
• The current capacity of your AC
adapter with a USB port is lower than
1.0 Adc.
Use an AC adapter with a USB port
with a current capacity equal to or
higher than 1.0 Adc.
• A USB port is used to connect to the
PC.
Remove the USB hub.
(A)
CHARGE indicator
3
If none of the above (1 to 2) is the case, the battery or junction may be faulty.
NOTICE
If the CHARGE indicator does not light up or
goes out soon, the battery may be fully
charged. Check the remaining power of the
battery using junction [A] or the system
information display.
If it becomes impossible to charge, the
CHARGE indicator (orange) or ERROR
indicator of the battery charger will blink.