Shimadzu Sonialvision Safire Скачать руководство пользователя страница 1

O P E R A T I O N  

G U I D E

O P E R A T I O N   G U I D E

M517-E077A

Содержание Sonialvision Safire

Страница 1: ...O P E R A T I O N G U I D E O P E R A T I O N G U I D E M517 E077A...

Страница 2: ...sely describes its basic operations Prior to using this guide make sure to carefully read all Operation Manual booklets of Sonialvision Safire II Safire 17 and fully understand them In case of Sonialv...

Страница 3: ...Enter Study 13 Defining usual study 13 Defining patient information in an emergency 14 Choosing types of study 15 Fluoroscopy Radiography 16 Setting radiography condition 16 Radiography 17 SPOT radio...

Страница 4: ...rator console Image monitor Exposure switch Mouse Keyboard Control cabinet Diagnostic table Subsystem control cabinet Flat panel detector Diagnostic table Selector attached mouse monitor and keyboard...

Страница 5: ...ge vertically Reverse the image horizontally Stop switch Adjusts the contrast of the image Adjusts the brightness of image Joystick Table imaging unit control lever F1 F5 Sets up the Subdivisional Acq...

Страница 6: ...mAs shuttle Adjust in large increments sec up down button Adjust in small increments sec shuttle Adjust in large increments AEC button Hand switch Density up down button X ray radiography button Radio...

Страница 7: ...study P 13 Choose type of study P 15 Set Fluo Rad condition P 16 Fluoroscopy Radiography P 17 Print image P 20 Send by DICOM P 23 Close study P 24 Shut down system P 9 Repeat as required Start up sys...

Страница 8: ...prox 2 seconds Image monitor peripherals and control cabinet are turned ON 1 2 3 5 0 5 Digital image processor While the system is running the power up self testing routine a splash screen appears Sta...

Страница 9: ...Click Yes The system will be automatically shut down and the control cabinet will be turned OFF X ray high voltage generator console 3 Turn OFF the X ray high voltage generator Press OFF ON lamp is t...

Страница 10: ...on system startup Perform when the system starts up 1 Start up the system After system startup an FPD calibration dialog appears A on diagnostic table console blinks and the message appears 2 Press a...

Страница 11: ...An FPD Calibration starts Close button appears when FPD calibration is complete 4 Click Close Make sure there are no personnel in the study room before performing FPD calibration procedure as the dia...

Страница 12: ...g Perform FPD calibration after the study is finished because the operation cannot be performed during study 1 Right click on the main image area The right click menu appears 2 Select FPD Calibration...

Страница 13: ...ard control panel A Patient List window appears 2 Click New A Patient Information window appears 2 Enter patient information Patient Name Patient ID Patient DOB Fields indicated by an asterisk are req...

Страница 14: ...dow appears 2 Click Emergency The Patient List window is closed and then the study starts The patient s information appears on upper left of the main image area The following patient information is au...

Страница 15: ...7 E077A Choosing types of study 1 Choose Cell Title according to types of study The top 4 APRs according to type of study appear Diagnostic table console display panel The top 4 APRs registered by dig...

Страница 16: ...Digital image processor T h e A P R s s e l e c t e d o n t h e diagnostic table console appear on the Standard control panel X ray high voltage generator console T h e r a d i o g r a p h y p r o g r...

Страница 17: ...py selection switch is not illuminated even if the foot switch is pressed Press the fluoroscopy selection switch to light 2 Press down the foot switch The exposure indicator illuminates The fluoroscop...

Страница 18: ...switch is pressed Press the fluoroscopy selection switch to light 2 Press down the foot switch The exposure indicator illuminates The fluoroscopy image appears on the main image area of digital image...

Страница 19: ...ove diagnostic table to starting point Press F5 SET until the key is highlighted Press F1 Cancel for canceling the exposure operation 5 Exposure Press and hold down the hand switch The tomography imag...

Страница 20: ...ct from Patient List Entire patient file or specific study can be printed 5Process Images Printing images Print by Print Image 1 Click A mark S appears in the lower right corner on the main image area...

Страница 21: ...area The Right click menu appears 2 Select Print Select H A mark H appears in the lower right corner of the main image area The mark H appears when the image to be printed is selected To delete the m...

Страница 22: ...rint Patient Either the patient file or specific study can be selected from Patient List window 3 Click either Print Patient or Print Study The Configure Print Settings dialog appears Clicking Print P...

Страница 23: ...ending by DICOM function Manual DICOM Send Option For manual DICOM send open the patient file including image and allow that image to be displayed on the main image area 1 Click on the Standard contro...

Страница 24: ...24 M517 E077A 6 C l o s e S t u d y Close Study 6 Closing active study 1 Click on the Standard control panel A confirmation dialog appears 2 Click OK The patient file is closed...

Страница 25: ...tic table operation Press the stop switch on either the diagnostic table console or diagnostic table Diagnostic table console Diagnostic table Recovery from emergency stop To recover from emergency st...

Страница 26: ...Radiography tube current e x c e e d e d s e t v a l u e 200 mA Measured kV OVER Measured tube voltage exceeded permitted range Starter ERR Starter is in abnormal situation or condition Starter is not...

Страница 27: ...R Setting out of range for mAs setting method Procedure Change the set value Increase radiography tube voltage or reduce radiography tube current Decrease radiography tube voltage or radiography tube...

Страница 28: ...cator on the console illuminates and one of the following error messages appears The system cannot expose while these messages are displayed Message Meaning Communication ERR Received radiographic con...

Страница 29: ...aning Position Detect Error XXX Position detect error in operating parts Position Error XXX Potentiometer break detect Motor Error XXX Motor error Procedure Reset by pushing STOP switch or re startup...

Страница 30: ...itch of PCU Application software Xcat for FPD control starts up automatically Approx 5 minutes is required to complete the startup 3 Shut down the system Turn ON the system again 4 Verify the FPD powe...

Страница 31: ......

Страница 32: ...10 Cable Add SHIMADZU TOKYO Overseas Telex No 0232 3291 SHMDT J KYOTO OFFICE 1 Nishinokyo Kuwabaracho Nakagyo ku Kyoto 604 8511 Japan Cable Add SHIMADZU KYOTO Overseas Telex No 05422 166 SHMDS J SHIMA...