Ǧͳ͸Ǧ

„

OTHERS  

• Data storage 

: By non-volatile memory (EEPROM) 

• Ambient temperate / humidity ranges for use 

: -10 - +50

Υ

 /below 90% RH   

  (on condition that there is no dew   
   condensation) 

• Temperature for storage 

: Between-20 and +65

Υ

• Over voltage category  : ll 
• Elevation 

: Max. 2000 m 

• Pollution class 

: 2 (IEC 60664) 

• Temperature range for maintaining accuracy 

: 23±5

Υ

• Power voltage 

: 100V-240V AC±10% (50/60 Hz),   
  24V AC±10% (50/ 60Hz),  
  24V DC±10%.   
  (One of the above to be specified) 

• Power consumption 

: 15VA maximum 

• Input noise removal ratio 

: Normal mode 60 dB minimum (50/60 Hz)   
  Common mode 140 dB minimum (50/60 Hz) 

• Applicable standards  : 
                           Safety  : IEC61010-1 , EN61010-1 
 

  IEC61010-2-030 , EN61010-2-030 

                           EMC   : EN61326-1 
• Insulation resistance 

:  

      Between input / output terminals and power terminal  

: 500V DC 20M

ȍ

 minimum 

      Between input/output terminals and protective conductor terminal  

: 500V DC 20M

ȍ

 minimum 

• Dielectric strength 

: 1 minute at 3000V AC between input/output   
  terminals and power terminal 
  1 minute at 1500V AC between power  
  terminal and protective conductor terminal 

• Protective structure 

: Only front panel has simple dustproof and drip  
  -proof structure (equivalent to IP66) 

 

   (Panel thickness :1.2-3.2mm) 

• Material of case 

: PPE resin molding (equivalent to UL94V-1) 

• External dimensions 

: SR82:H72 × W72 × D111mm  
           (Inside depth of panel: 100mm)  
  SR83:H96 × W96 × D111mm  
           (Inside depth of panel: 100mm) 
  SR84:H96 × W48 × D111mm  
           (Inside depth of panel: 100mm) 

• Mounting 

: Push-in panel (one-touch mount) 

• Applicable panel thickness 

: 1.0 - 4.0 mm 

• Panel cutout size 

 

                                SR82: H68 × W68mm  
                                SR83: H92 × W92mm  
                                SR84: H92 × W45mm 
• Weight 

 

                                SR82: 300g 
                                SR83: 420g 
                                SR84: 280g 

PRINTED IN JAPAN

Содержание SR80 Series

Страница 1: ...f it goes out of the range a rise in temperature will reduce the product life and or result in problems with the product The output terminal should be connected with a device which meets IEC61010 requ...

Страница 2: ...k alarm 50A 1 Remote input 2 00 None 14 4 20mA DC Not insulated 15 1 5V DC Not insulated 16 0 10V DC Not insulated Analog output 3 0 None 3 0 10mV DC 4 4 20mA DC 6 0 10V DC Communication 3 0 None 5 RS...

Страница 3: ...high voltage power lines 6 Shield wiring one point grounding works effectively against static induction noise 7 Twisting the input signal wire at equal intervals is effective against electromagnetic i...

Страница 4: ...ransformer CT Pass one load wire through the hole specifically provided or CT CT terminals on the secondary side are wired to the CT input terminal of the SR80 controller 1 SR82 2 SR83 1 Output 2 Outp...

Страница 5: ...y parameter screen the mode 0 basic screen returns onto the display 2 parameter key When pressed on any of the mode 0 and 1 screen groups the next screen appears When this key is pressed continuously...

Страница 6: ...digit digit digit digit digit digit...

Страница 7: ...0 32 screens are the same as the other PID parameters Initial value 2 0 digit Setting range 1 1000 digit digit Initial value 2 0 digit Setting range 1 1000 digit Initial value 2 0 digit Setting range...

Страница 8: ...digit digit It is conditional that rE_L rE_H It is conditional that rE_L rE_H...

Страница 9: ......

Страница 10: ...s effect when DI input turns ON When to detect external control input signal Level input The action is maintained as long as the contact remains ON Edge input The action is maintained even when the co...

Страница 11: ...key for confirmation The AT lamp goes out Note When AT is cancelled in the mid operation PID values remain unchanged AT is automatically cancelled under the following conditions 1 Output value remains...

Страница 12: ...STBY EXE 3 SV is changed where standby set value is a deviation value Except during remote input though When the standby action setting is changed to oFF or 4 while standby is in action the standby a...

Страница 13: ...lamp display Control output OUT1 2 green Event action EV1 2 3 orange Auto tuning action AT green Manual control action MAN green Set value bias action SV2 SB green Remote action REM green Standby acti...

Страница 14: ...ual switching Front key operation or DI external switching input through communication Manual control output 0 0 100 0 out of output limiter range possible Setting resolution 0 1 Manual automatic cont...

Страница 15: ...1 RS 232C RS 485 Communication system RS 232C 3 line half duplex system RS 485 2 line half duplex multiple drop bus system Synchronization system Start stop synchronization system Communication distan...

Страница 16: ...tween input output terminals and power terminal 500V DC 20M minimum Between input output terminals and protective conductor terminal 500V DC 20M minimum Dielectric strength 1 minute at 3000V AC betwee...

Отзывы: