FP23 2-input 

I n s t r u c t i o n   M a n u a l   

http://www.shimaden.co.jp

„

  F o r   q u e s t i o n s ,   p l e a s e   c o n t a c t 

Y O U R   L O C A L   A G E N T 

or

e x p - d e p t @ s h i m a d e n . c o . j p

ڦ

LCD Flow Chart 

ڦ

Frequently-used Keys for LCD 

Move to 0-0 Screen 

(E.G.: 2-5

0-0)

DISP 

Move from a 0 screen of a group to 
another 

(E.G.: 0-0

1-0

2-0) 

Move to the group’s 0 screen 

(E.G.: 2-4

2-0)

GRP

Move to the next screen in a group 

(E.G.: 2-0

2-1

2-2)

SCRN 

Move to the previous screen in a 
group 

(E.G.: 2-2

2-1

2-0)

ENT 

+

SCRN 

Modify the Step No. at 0-0 Screen 
Move to the step screens from 2-0 
Screen

(E.G.: 2-0

2S-0)

STEP 

Modify the Pattern No. at 0-0 
Screen

Move to Program screens from 
Step screens

(E.G.: 2S-1

2-1)

PTN 

Move to the next parameter in a 
screen

(E.G.: AT

MAN at 1-1)   (E.G.: CH1 at 1-0) 

(E.G.: Start PTN

CH1 at 1-2)

Modify a value for a parameter 

(E.G.: P at 3-1) 

(E.G.: CH1

 CH2 at 4-4)

or

Move from digit to digit for a value

Register a modified value 

ENT 

6FUHHQVWKDWDUHDOZD\VGLVSOD\HG

1RQVWDQGDUG
VFUHHQ

6FUHHQVWKDWDUHGLVSOD\HGGHSHQGLQJ
RQRSWLRQVVHWXSYDOXHV

6WDQGDUGVFUHHQ

Please see pages xii and xiii in the FP23 series digital controller 
instruction manual (Detailed version) 2-input. 

Содержание FP23 Series

Страница 1: ...lagged or lagged type When wiring this device tighten the terminal connections firmly Use the device with the power voltage and frequency within their rated ranges Do not apply a voltage or current outside of the input rating to the input terminal Doing so might shorten the service life of this device or cause it to malfunction The voltage and current of the load connected to the output terminal s...

Страница 2: ...llector output for external control output terminals DO Open collector output for connecting to relays DO1 to DO3 Darlington output Output rating 24V DC 50mA max DO terminals other than DO1 to DO3 All the terminals other than DO1 to DO3 are open collector output terminals 24V DC 8mA max Note that the output ratings differ from that of DO1 to DO3 Termi nal No Symbol Description 1 2 Analog output 1 ...

Страница 3: ...ed by an input error MAN green Blinks when control output is set to manual operation MAN FIX green Lights in the FIX mode EV1 orange Lights during EV1 action EV2 orange Lights during EV2 action EV3 orange Lights during EV3 action DO1 orange Lights during DO1 action DO2 orange Lights during DO2 action DO3 orange Lights during DO3 action DO4 orange Lights during DO4 action DO5 orange Lights during D...

Страница 4: ...2 0 2 1 2 2 SCRN Move to the previous screen in a group E G 2 2 2 1 2 0 ENT SCRN Modify the Step No at 0 0 Screen Move to the step screens from 2 0 Screen E G 2 0 2S 0 STEP Modify the Pattern No at 0 0 Screen Move to Program screens from Step screens E G 2S 1 2 1 PTN Move to the next parameter in a screen E G AT MAN at 1 1 E G CH1 at 1 0 E G Start PTN CH1 at 1 2 Modify a value for a parameter E G ...

Отзывы: