FP23 2-input 

I n s t r u c t i o n   M a n u a l   

http://www.shimaden.co.jp

„

  F o r   q u e s t i o n s ,   p l e a s e   c o n t a c t 

Y O U R   L O C A L   A G E N T 

or

e x p - d e p t @ s h i m a d e n . c o . j p

ڦ

External Dimensions   

ڦ

Panel Cutout Dimensions 

ڦ

Mounting

Caution

To ensure safety and maintain the functions of this device, do not disassemble this device. 

If this device must be disassembled for replacement or repair, contact your dealer. 

Follow the procedure below to mount this device on a panel. 

1.

Drill mounting holes referring to the panel cutout dimensions described in the previous 

section.

The applicable thickness of the mounting panel is 1.0 to 8.0 mm. 

2.

Press this device into the panel from the front of the panel. 

3.

Insert the mounting fixtures at the top and bottom of this device, and tighten the screws 

from behind to fasten the device in place. 

4.

Over-tightening the screws may deform or damage the device housing. 

Take care not to tighten the screws too tight.

5.

After completing wiring after installation, attach the terminal cover.

ڦ

Rear Terminal Arrangement Diagram 

ڦ

Wiring Example of Open Collector Output 

The following is an example of wiring open collector output for external control output 
terminals (DO). 

Open collector output (for connecting to relays) 

DO1 to DO3: Darlington output 
Output rating: 24V DC 50mA max. 

DO terminals other than DO1 to DO3 

All the terminals other than DO1 to DO3 are open collector output terminals (24V DC 8mA max.).   
Note that the output ratings differ from that of DO1 to DO3. 

Termi

nal 

No 

Symbol Description 

1

2

+

-

Analog output 1 (optional)

3

4

+

-

Analog output 2 or Sensor 
power supply (optional) 

5

6

+

-

Heater Break alarm   
CT input (optional) 

8

10

+

-

mV, 
thermocouple 
input

Input 1 

8

10

11

A

B

B

RTD input 

7

10

+

-

V, mA input 

45

46

L

N

Power supply 

 

47

48

Grounding (internal 
shorting across terminals)

49

50

51

COM + 

NO - 

NC

Control output 1 

23 COM 

External 
control
output DO 

(standard) 

24

25

26

DO1

DO2

DO3

Darlington

output 

27

28

DO4

DO5

Open
collector 
output 

29

30

31

32

33

DI1 

DI2 

DI3 

DI4 

COM

External control output DI

(standard) 

Termi

nal

No

Symbol

Description 

34

35

36

37

DO6

DO7

DO8

DO9

External control output DO

Open collector output 

(optional) 

38

39

40

41

42

43

44

DI5 

DI6 

DI7 

DI8 

DI9 

DI10 

COM

External input DI5 to DI10

(optional) 

12

13

14

SG

SD + 

RD - 

Communication function 
(optional) 

15

16

17

COM +

NO - 

NC

Control output 2 
(optional) 

19

21

+

-

mV, 
thermocouple 
input

Input 2

19

21

22

A

B

B

RTD input 

18

21

+

-

V, mA input 

A receiving resistor of 1/2W 250

ȍ

 0.1% is 

attached across input terminals (7-10) for 

use for the 0 to 20mA, and 4 to 20mA 

inputs.

➃Ꮚ䜹䝞䞊௜䚷䚷༢఩䠖㼙㼙

with terminal cover 

Unit: mm 

Unit: mm 

or more

or more

Mounting fixture 

FP23

Mounting fixture 

࣮ࣜࣞ

Содержание FP23 Series

Страница 1: ...lagged or lagged type When wiring this device tighten the terminal connections firmly Use the device with the power voltage and frequency within their rated ranges Do not apply a voltage or current outside of the input rating to the input terminal Doing so might shorten the service life of this device or cause it to malfunction The voltage and current of the load connected to the output terminal s...

Страница 2: ...llector output for external control output terminals DO Open collector output for connecting to relays DO1 to DO3 Darlington output Output rating 24V DC 50mA max DO terminals other than DO1 to DO3 All the terminals other than DO1 to DO3 are open collector output terminals 24V DC 8mA max Note that the output ratings differ from that of DO1 to DO3 Termi nal No Symbol Description 1 2 Analog output 1 ...

Страница 3: ...ed by an input error MAN green Blinks when control output is set to manual operation MAN FIX green Lights in the FIX mode EV1 orange Lights during EV1 action EV2 orange Lights during EV2 action EV3 orange Lights during EV3 action DO1 orange Lights during DO1 action DO2 orange Lights during DO2 action DO3 orange Lights during DO3 action DO4 orange Lights during DO4 action DO5 orange Lights during D...

Страница 4: ...2 0 2 1 2 2 SCRN Move to the previous screen in a group E G 2 2 2 1 2 0 ENT SCRN Modify the Step No at 0 0 Screen Move to the step screens from 2 0 Screen E G 2 0 2S 0 STEP Modify the Pattern No at 0 0 Screen Move to Program screens from Step screens E G 2S 1 2 1 PTN Move to the next parameter in a screen E G AT MAN at 1 1 E G CH1 at 1 0 E G Start PTN CH1 at 1 2 Modify a value for a parameter E G ...

Отзывы: