OPEN
FRONT
1" MINIMUM CLEARANCE
AROUND HOT WATER
PIPES AND VENT PIPE
Figure 1-2
Alcove Installation - Minimum Required Clearances
1" MINIMUM CLEARANCE
AROUND HOT WATER
PIPES AND VENT PIPE
CLOSED DOOR
VENTILATING
AIR OPENING
VENTILATING
AIR OPENING
*
AREA OF EACH OPENING:
1 SQ. INCH PER 1000 BTU PER HOUR INPUT
WITH A MINIMUM OF 100 SQ. INCHES
6"
6"
Figure 1-1
Closet Installation - Minimum Required Clearances
WARNING
For closet installations, CPVC
material MUST BE used in a closet
structure due to elevated
temperatures. Failure to follow this
warning could result in fire,
personal injury, or death.
9
1
Determine water heater location
(continued)
RECOMMENDED SERVICE
CLEARANCES:
Top
- 18" (457 mm)
Right Side - 24" (610 mm)
Front -
24" (610 mm)
RECOMMENDED SERVICE
CLEARANCES:
Top
- 18" (457 mm)
Right Side - 24" (610 mm)
Front -
24" (610 mm)
Installation & Service Manual
TM
WARNING
For alcove installations, CPVC
material MUST BE used in an
alcove structure due to elevated
temperatures. Failure to follow this
warning could result in fire,
personal injury, or death.