![Shido DC 25.0 Скачать руководство пользователя страница 3](http://html.mh-extra.com/html/shido/dc-25-0/dc-25-0_instructions-for-use-manual_1256759003.webp)
•
Charge in properly ventilated and dry environments: do not expose to rain or snow.
•
Make sure that the charger is disconnected from the mains before connecting, or
disconnecting, the charging cables to the battery.
•
When charging never place the charger over the battery.
•
The liquid inside the batteries is corrosive, if there is accidental contact of the acid with
the skin or eyes rinse immediately with water and seek medical advice.
•
The improper use of the charger, or the tampering of the electronic circuit inside the
device, will void the warranty.
•
In case of damage, the power cord of the appliance must be replaced by authorized
technicians, since intervention requires the use of special tools.
•
Repair or maintenance of the appliance must be carried out only by qualified
personnel.
•
Use the charger only after carefully reading the instruction manual.
CHARGING
Charging batteries connected to the vehicle
1.
Before starting ensure that the power cord is disconnected from the mains socket.
2.
Locate the vehicles main earth point; generally connected to the negative terminal of the battery.
3.
Connect the output lead with red clamp to the positive (+) pole of the battery.
4.
Connect the output lead with black clamp to the ground of the vehicle, away from the battery and any fuel lines.
Charging batteries not connected to a vehicle
1.
Before starting ensure that the power cord is disconnected from the mains socket.
2.
Connect the output conductor with red clamps to the positive (+) pole of the battery.
3.
Connect the output conductor with black clamps to the negative (-) pole of the battery.
4.
Caution:
ensure that both clamps have adequate contact with the battery terminals.
HOW TO USE THE BATTERY CHARGER
1.
Once the output clamps have been connected to the battery, connect the power cord to the mains socket,
making sure that the voltage corresponds to the rated voltage of the charger.
2.
With the cha
rger in “stand-by” mode, set the appropriate charge parameters using the mode button to select
the correct voltage.
For
12V batteries
the following charging parameters can be selected
via the “Function" button:
5A
For charging 12V 5Ah to 100Ah batteries
Maintenance for 12V 5Ah to 150Ah batteries
Suitable for charging WET and Gel batteries
12.5A
For charging 12V 70Ah to 250Ah batteries
Maintenance for 12V 70Ah to 360Ah batteries
Suitable for charging WET and Gel batteries
25A
For charging 12V 150Ah to 550Ah batteries
Maintenance for 12V 150ah to 800Ah batteries
Suitable for charging WET and Gel batteries
5A
For charging 12V 5Ah to 100Ah batteries
Maintenance for 12V 5Ah to 150Ah batteries
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries
with temperatures below 5C°
12.5A
For charging 12V 70Ah to 250Ah batteries
Maintenance for 12V 70Ah to 360Ah batteries
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries
with temperatures below 5C°
25A
For charging 12V 150Ah to 550Ah batteries
Maintenance for 12V 150ah to 800Ah batteries
Suitable for charging AGM-START&STOP and AGM-SPIRAL and EFB or WET batteries
with temperatures below 5C°