A. The stove will shut off when the fire goes out and the exhaust temperature drops below 120
°
F (49
°
C).
B. The stove has a high temperature safety switch. If the temperature on the hopper reaches 200
°
F
(93
°
C), the auger will automatically stop and the stove will shut down when the exhaust temperature
cools #4 light flashes. Dealer will have to reset the sensor. If this happens, call your local dealer to reset
the 200
°
F (93
°
C) high limit switch.
ALSO FIND THE REASONS WHY THE UNIT OVERHEATED.
C) The unit is equipped with a vacuum switch to monitor the venting; if it becomes blocked the vacuum
switch will turn off the auger and the #2 light on the control board will flash.
o
peRating
y
ouR
p
eLLet
S
tove
:
PRE-BURN INSTRUCTIONS
: The burn pot liner holes must be clear and the liner installed properly
against the ignitor tube for proper operation. Check the hopper for enough pellets to start the unit.
DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.
Note:
The thermostat mode can be changed during normal operation.
Operating Instructions
Figure 2: Thermostat Switch in
MANUAL position.
Figure 3: Thermostat Switch in
HIGH/LOW position.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
HIGH/LOW MODE:
(Requires a thermostat)
INITIAL START-UP
: See manual mode above.
OPERATION
: When the thermostat calls for heat (contacts are closed)
the stove settings are adjustable as per Manual Mode. When the
thermostat contacts open, the HEAT LEVEL and Fans will drop down to
the LOW setting until the thermostat contacts close again. *The LOW
heat setting can be adjusted for different fuel qualities (see “
O
perating
i
nstructiOns
- c
OntrOl
B
Oard
F
unctiOns
”). The stove will come back to the
previous HEAT LEVEL setting when the thermostat contacts close again.
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
ROOM AIR
FAN ON/OFF
ON/OFF
FEED RATE
TRIM
COMBUSTION
BLOWER TRIM
HEAT LEVEL
AUTO/OFF
HIGH/LOW
MANUAL
AUGER
C-11625
MODE
1
2
3
4
5
6
8
7
9
MANUAL MODE:
All control of circuit board function is adjusted at the circuit board.
To START:
Press the ON / OFF button. The stove will turn on. The
system light will flash. The Auger Light will flash with each pulse of the
auger (the Auger Feed Rate is pre-programmed during start-up). The
Heat Level Indicator will show the Heat Level that the stove will run at
after start-up and can be adjusted but the change will not take affect
until the start -up has finished.
If this is the first time the unit has been started or the unit has run out
of fuel, the auger will need to be primed. This can be done by restarting the unit five (5) minutes into its
start-up or by putting a small hand full of pellets into the burnpot.
To OPERATE:
When a fire has been established, the System Light will turn solid (after approximately
10 - 15 minutes) and the Auger Light will continue to flash to the corresponding Heat Level setting.
The convection blower (room air blower) will turn on. The speed of this blower is controlled by the setting
of the heat level output indicator. The convection blower can be turned OFF by depressing the convection
blower control button. For the best efficiency the convection blower should be left on at all times.
Содержание GF55
Страница 29: ...29 of 194 29 of 194...
Страница 30: ...30 of 194 30 of 194...
Страница 31: ...31 of 194 31 of 194...
Страница 32: ...32 of 194 32 of 194...
Страница 33: ...33 of 194 33 of 194...
Страница 38: ...38 of 194 38 of 194...
Страница 39: ...39 of 194 39 of 194...
Страница 40: ...40 of 194 40 of 194...
Страница 41: ...41 of 194 41 of 194...
Страница 42: ...42 of 194 42 of 194...
Страница 45: ...1 19 2018 45 of 194 45 of 194...
Страница 48: ...1 19 2018 48 of 194 48 of 194...
Страница 49: ...49 of 194 49 of 194...
Страница 50: ...50 of 194 50 of 194...
Страница 52: ...52 of 194 52 of 194...
Страница 53: ...53 of 194 53 of 194...
Страница 114: ...43 MERIDIAN Components May 2015 4 11 1 17 6 2 12 7 5 3 39 Parts Diagram Components...
Страница 116: ...45 MERIDIAN Insert Steel Parts May 2011 48 50 49 52 53 51 46 47 37 36 34 45 33 32 35 40a Parts Diagram Insert Steel...
Страница 117: ...46 Notes...
Страница 155: ...36 MERIDIAN CAST IRON Components May 2015 4 11 1 10 6 2 9 7 5 3 8 Parts Diagram Components...
Страница 157: ...38 Notes...