![Sherwood Scuba AMPHOS AIR 2.0 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/sherwood-scuba/amphos-air-2-0/amphos-air-2-0_manual_1256672045.webp)
45
AMPHOS AIR 2.0 DC MANUAL
© Pelagic, 2019
Doc. No. 12-79 3 9 -r01 (11/12/19 )
NOTE: The Cover O-ring must be a genuine Sherwood part that can be purchased from an Authorized Sherwood
Dealer. Use of any other O-ring will void the warranty.
• Carefully place the Battery Cover (with O-ring) into position on the rim of the Battery Compartment, then press it evenly and completely
down into place.
• Maintain the Cover securely in place and turn it counter clockwise 10 degrees using the Cover tool (Fig. 126), or by pushing the lower
portion to the right while pushing the upper portion to the left using your fingers (Fig. 127).
Testing
• Activate the unit and observe the LCD is consistently clear and sharp in contrast throughout the screen.
• Set the Watch functions.
• Verify all Set Points prior to diving.
• If any portions of the display are missing or appear dim, or if a Low Battery condition is indicated, return your AMPHOS AIR 2.0 to an
Authorized Sherwood Dealer for a complete evaluation before attempting to use it.
TRT (Transmitter) Battery Removal
Locate the Battery Cover on the End of the Housing:
• Apply a coin to the recessed slot of the Cover and turn it counter clockwise out of the Housing (Fig. 128).
• Remove the Battery from the Battery Compartment and discard according to local regulations governing disposal of Lithium batteries.
Inspection
• Closely check all of the sealing surfaces for any signs of damage that might impair proper sealing.
• Inspect the Housingto ensure it is not cracked or damaged.
WARNING: If damage or corrosion is found, return your TRT to an Authorized Sherwood Dealer, and DO NOT attempt
to use it until it has received factory prescribed service.
• Remove the Battery Cover O-ring and inspect it for any signs of deterioration or deformity. DO NOT use tools to remove the O-ring.
• To ensure proper sealing, O-ring replacement is highly recommended each time a Battery is replaced.
• Closely examine the threads of the Battery Cover and Housing for any signs of damage that might prevent proper threading.
• Closely examine the inside of the Battery Compartment for any signs of corrosion indicating entrance of moisture.
• If corrosion is found, return the TRT to an Authorized Sherwood Dealer, and DO NOT attempt to use it until it has received factory
service.
• If moisture is found, it is best to have the unit inspected and cleaned by an Authorized Sherwood Dealer.
TRT Battery Installation
• Lightly lubricate the new Battery Cap O-ring with silicone grease and install it onto the Battery Cap. DO NOT roll the O-ring over the
threads, instead stretch it slightly to work it down over the slotted end of the Cap into the groove at the base of the threads (Fig. 129).
NOTE: The TRT's O-ring must be a genuine Sherwood part that can be purchased from an Authorized Sherwood Dealer.
Use of any other O-ring will void the warranty.
• Place a new 3 volt, CR2, Lithium Battery (Duracell model DL-CR2 or equivalent) positive (+) side down into the Battery Compartment
with the negative end facing up/out (Fig. 130).
• Ensure that the Battery is properly oriented and the Cover O-ring is evenly seated around the Battery Cover.
• Carefully place the Battery Cover with Spring into the Housing and turn clockwise slowly by hand to ensure proper threading. Apply a
coin and tighten until secure. The outer surface of the Battery Cover should be flush with the outer surface of the Housing (Fig. 131).
AMPHOS AIR 2.0 System Testing
• Pressurize the Regulator Assembly (and Transmitter).
• Verify that the Link icon is displayed.
• Press the S button for 2 seconds to check the Status screens.
• If a Low Battery Condition is indicated, return your AMPHOS AIR 2.0 with TRT to an Authorized Sherwood Dealer for a complete
evaluation before attempting to use it.
INSTALLING A TRANSMITTER ON A REGULATOR
To install the TRT on the Regulator First Stage:
• Remove the existing Pressure Gauge and High Pressure Hose, or the High Pressure Port Plug from the port marked HP using the proper
size hex key.
• Lightly lubricate the O-ring and threads of the Transmitter fitting with a halocarbon based lubricant such as Christo-Lube MCG111
(provided in Sherwood Battery Kits).
• Thread the Transmitter clockwise by hand into the Regulator's HP Port (Fig. 132) and tighten until secure with a 5/8" open-end wrench.
• Attach the Regulator First Stage to a full SCUBA Tank and pressurize by slowly opening the tank valve, listening for any indication of air
leaking around the Fitting.
• If air leakage is present, DO NOT use, take the complete regulator assembly to an Authorized Sherwood dealer for inspection and
service.
TRANSMITTER COMPATIBILITY WITH NITROX
When packaged and shipped from the factory, Sherwood AMPHOS AIR 2.0 Transmitters are rated for use with compressed Air and/or
nitrogen-oxygen (Nitrox) breathing gas mixtures containing up to 99% O2 by volume and with 100% O2.
Fig. 126 - BATTERY Cover
INSTALLATION
Fig. 127 - ALT BATTERY
Cover INSTALLATION
Fig. 128 - TRT BATTERY
Cover REMOVAL
Fig. 129 - TRT O-RING
INSTALLATION
Fig. 130 - TRT BATTERY
ORIENTATION
Battery
(+) ( - )
Fig. 131 - TRT BATTERY
Cover INSTALLED
Fig. 132 -TRT INSTALLED
ON FIRST STAGE
Содержание AMPHOS AIR 2.0
Страница 5: ...5 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 FEATURES DISPLAYS...
Страница 8: ...8 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 WATCH FEATURES DISPLAYS...
Страница 12: ...12 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 DIVE COMPUTER FEATURES DISPLAYS...
Страница 14: ...14 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 DIVE COMPUTER SURFACE MODES...
Страница 23: ...23 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NORM DIVE MODES...
Страница 28: ...28 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 CAUTIONARY MODES...
Страница 33: ...33 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 SWITCHING GAS MIXES TRANSMITTERS...
Страница 43: ...43 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 REFERENCE...
Страница 53: ...53 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NOTES...
Страница 54: ...54 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 AMPHOS AIR 2 0 DIVE COMPUTER MANUAL...