![Sherwood Scuba AMPHOS AIR 2.0 Скачать руководство пользователя страница 34](http://html1.mh-extra.com/html/sherwood-scuba/amphos-air-2-0/amphos-air-2-0_manual_1256672034.webp)
34
AMPHOS AIR 2.0 DC MANUAL
© Pelagic, 2019
Doc. No. 12-79 3 9 -r01 (11/12/19 )
SWITCHING (NORM)
During NORM Dives, the AMPHOS AIR 2.0 can be manually switched from Gas 1 to Gas 2, changing FO2 displays and calculations, and if
TRTs (Transmitters) are used, changing Pressure related displays and calculations from TRT 1 to TRT 2.
Every dive begins with Gas 1, and 10 minutes after surfacing from a multiple gas dive, operation defaults to the Gas 1 FO2.
Access to Switching screens can only be accomplished during the time that a Dive Main screen is being displayed and cannot be performed
during the time that an Alarm is sounding or while on the surface.
If a Switch to a new Gas would expose the diver to a prohibitive PO2 level of 1.60 ATA or greater, the Audible will sound during which a mes-
sage will be displayed for 10 seconds (Fig. 95).
Due to the possibility that sufficient air may not be available in the Switch From tank to complete the dive, the Switch to the prohibitive mix
can still be made. If the Switch is made to the prohibitive mix, the High PO2 Alarm will activate.
Switching of Gas mixes can only to be performed during the time that a Gas Switch Preview screen is being displayed. These are accessed
from a Dive Main screen.
• M (2 sec) while viewing a Dive Main will access the Gas/TRT 1 Switch Preview screen.
GAS/TRT 1 SWITCH PREVIEW
, information includes (Fig. 96) -
> Link icon.
> Graphic GAS 1.
> Current PO2 value with PO2 icon, based on current depth and FO2 displayed.
> FO2 set for Gas 1 with FO2 icon.
> Gas/TRT (tank) 1 icon.
> NX icon if Nitrox.
> Pressure with PSI (or BAR) icon.
• M (< 2 sec) to access the Gas/TRT 2 Switch Preview.
• S (< 2 sec) to switch to Gas/TRT 1, after 3 sec, then revert to the Main with calculations/displays based on Gas/TRT 1*.
• Operation will revert to the Dive Main after 10 seconds if no button action.
GAS/TRT 2 SWITCH PREVIEW
, information includes (Fig. 97) -
> Link icon.
> Graphic GAS 2.
> Current PO2 value with PO2 icon, based on current depth and FO2 displayed.
> FO2 set for Gas 2 with FO2 icon.
> Gas/TRT (tank) 2 icon.
> NX icon if Nitrox.
> Pressure with PSI (or BAR) icon.
• M (< 2 sec) to revert to Dive Main.
• S (< 2 sec) to switch to Gas/TRT 2, after 3 sec, then revert to the Main with calculations/displays based on Gas/TRT 2*.
• Operation will revert to the Dive Main after 10 seconds if no button action.
*If a TRT is not responding after the switch is made, the Link icon and 00 PSI (BAR) will flash (like lost link) and ATR (on the ALT) will be 0
(min).
Fig. 95 - DON'T SWITCH
GAS ALARM
Fig. 96 - GAS/TRT 1
PREVIEW
Fig. 97 - GAS/TRT 2
PREVIEW
Содержание AMPHOS AIR 2.0
Страница 5: ...5 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 FEATURES DISPLAYS...
Страница 8: ...8 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 WATCH FEATURES DISPLAYS...
Страница 12: ...12 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 DIVE COMPUTER FEATURES DISPLAYS...
Страница 14: ...14 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 DIVE COMPUTER SURFACE MODES...
Страница 23: ...23 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NORM DIVE MODES...
Страница 28: ...28 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 CAUTIONARY MODES...
Страница 33: ...33 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 SWITCHING GAS MIXES TRANSMITTERS...
Страница 43: ...43 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 REFERENCE...
Страница 53: ...53 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 NOTES...
Страница 54: ...54 AMPHOS AIR 2 0 DC MANUAL Pelagic 2019 Doc No 12 79 3 9 r01 11 12 19 AMPHOS AIR 2 0 DIVE COMPUTER MANUAL...