Component Function and Identification
C
Fig. 1
E
F
D
A
G
J
B
H
K
04512A
A
Motor (Under shield shown)
DC motor, 120 Vac, 15A, 1 phase
B
Pressure Adjusting Knob
Controls fluid outlet pressure
C
ON/OFF Switch
Power switch that controls 120 Vac main power to sprayer
D
Drive Assembly
Transfers power from DC motor to the displacement pump
E
Fluid Filter
Filter of fluid between source and spray gun
F
Fluid Outlet
Spray gun operation is connected here
G
Pail Hanger
Container for fluid to be sprayed may be hung here
H
Displacement Pump
Transfers fluid to be sprayed from source through spray gun
J
Pressure Drain Valve
Relieves fluid outlet pressure when open
R
K
Pressure Control
Controls motor speed to maintain fluid outlet pressure at displacement
pump outlet. Works with pressure adjusting knob.