VIII.
Troubleshooting
Problems
Causes
Solutions
The motor fails to
run after being
switched powered
on.
·
The pump pressure
has been set at the
min value.
·
Fuse burnt-out
·
Battery out of power
·
Power switch has been
damaged
·
Battery wire connector
disconnected
·
Motor damaged
Potentiometer
has
been damaged.
·
Turn
the
knob
clockwise to increase
the pressure.
·
Replace
·
Recharge
·
Replace the switch
·
Disassemble the base
to
reconnect
the
wires.
·
Replace the motor
Replace
the
potentiometer.
Abnormal sounds
heard while the
motor rotates
·
The fastening screws of
the pump are loose
·
Tighten the screws
Leakage occurs to
the underside of the
base
·
The inlet / outlet pipes
of the pump have
loosened or broken
·
Disassemble the base
to tighten the pipe
clamp / replace pipe.
Poor atomization
results
·
Pump pressure too low
·
The holes inside the
nozzle
tip
are
blocked.
·
The nozzle hole has
worn out.
·
The spraying nozzle
sheet
has
been
inversely assembled.
·
Pi pe joints may
·
Turn
the
knob
clockwise to increase
the pressure.
·
Remove the impurities
·
Replace the Nozzel.
·
Correct it
·
Tighten the joints
loosen.
·
Battery short of
power
·
One inlet valve or
outlet valve of the
pump
has
been
jammed to reduce the
pressure by 50%.
·
Recharge
the
battery.
·
Remove the base.
Pump clean water
while knocking at the
pump head gently.
Disassemble
the
pump
housing
to
repair.
IX.
Packing List
S/N
Description
Unit Qty.
Remarks
1
Sprayer Body
unit
1
In addition,
Brass
multi-purpose
spraying
lance and
spare
nozzles are
available for
purchasing
separately
2
User’s Manual
Pc(s)
1
3
Four hole adjustable
spraying nozzle
Pc(s)
1
4
Fan spraying nozzle
Pc(s)
1
5
30
°
Doubl e spraying nozzle Pc(s)
1
6
split coupling
Pc(s)
2
7
spray boom O-ring
∅
15
×
3
Pc(s)
2
8
O-RING
∅
20.6
×
3
Pc(s)
1
9
Valve plug O-RING
∅
9.5
×
1.9
Pc(s)
1
10
Seal Gasket
∅
16
×
∅
11
×
2
Pc(s)
2
11
Seal Ring
∅
8.2
×
∅
4
×
2.5
Pc(s)
1
12
Fus e
∅
5*20 5A
Pc(s)
1
Содержание SX-MD16E