![SHERCO ST 125 Скачать руководство пользователя страница 45](http://html1.mh-extra.com/html/sherco/st-125/st-125_workshop-manual_1256240045.webp)
43
ST SERIES
ELECTRICAL PART
❱❘ Temperature sensor
•
Drain the coolant.
•
Remove the radiator temperature sensor.
•
Immerse the sensor
[1]
in a container filled
with coolant
[2],
making sure to leave the
terminals asleep with the liquid.
•
Immerse a thermometer
[3]
in the liquid so
as to control its temperature.
•
Heat the liquid slowly and check the
resistance of the sensor using a connected
multimeter as in the diagram according to
the temperature of the liquid, refer to the
table below.
❱❘
Ventilator
•
Disconnect the fan from the harness.
•
Connect a 12V battery directly to the fan as
shown in the diagram.
•
Check that the fan rotates correctly without
any hard point or abnormal noise.
TEMPS (°C)
RESISTANCE (Ω)
25
3000
30
2415
40
1620
50
1081
60
748
70
528
80
379
90
278
100
206