background image

User Manual

 

ATC-3001 1-port Modbus Gateway

 

 

 

Copyright 

©

 2011

 

SHENZHEN ATC TECHNOLOGY CO., LTD.   

29

 

 

 

 

B.2 Software Specifications 

Item 

Specifications 

Protocol 

§

 

TCP/IP, UDP, HTTP, SNMP, ARP, Telnet, ICMP, BOOTP, DHCP 

Configuration 

§

 

Configuration  information  for  both  TCP/IP  and  serial  ports  is  kept  in 
the EEPROM. 

§

 

Configuration  utilities  of  Windows  95/98/2000/NT/XP/2003  are 
provided for configuring settings. 

Internal Buffer Size 

§

 

TCP receiving buffer size = 8K bytes 

§

 

TCP transmitting buffer size = 16K bytes 

§

 

RS-232 or RS-485/RS-422 receiving buffer size = 4K bytes   

§

 

RS-232 or RS-485/RS-422 transmitting buffer size = 4K bytes 

B.3 Panel Layout and Connector Pin Assignments 

B.3.1 Pin Assignments 

DB9 Pin Assignments 

The pin assignments of DB9 connector on ATC-3001 are shown in the following table: 

 

Pin# 

 

RS-232 

Full Duplex 

for ATC-3001 Model 

  DCD 

  RXD 

  TXD 

  DTR 

  SG (Signal Ground) 

  DSR 

  RTS 

  CTS 

  N/A 

 

Terminal Block Pin Assignments 

The pin assignments of Terminal Block connector on ATC-3001 are shown in the following table: 

Pin# 

 

RS422/4-Wire RS-485 

  Full Duplex 

For

 

ATC-3001

 

 

2-Wire RS-485 

  Half Duplex 

For

 

ATC-3001 

  T+ 

  Data+ 

  T- 

  Data- 

 

R+ 

 

NC 

  R- 

  NC 

Содержание ATC-3001

Страница 1: ...Model ATC 3001 1 port Modbus Gateway User s Manual Updated on 2011 01 11 Tel 86 755 8345 3318 Fax 86 755 8355 5891 http www szatc com...

Страница 2: ...transmitted stored in a retrieval system or translated into any human or computer language in any form by any means in whole or in part without the prior express written consent of SHENZHEN ATC TECHN...

Страница 3: ...2 Configuration by Telnet Utility 6 3 2 1 Login to the System 6 3 2 2 IP Setup 7 3 2 3 Gateway Setup 7 3 2 4 Subnet Mask Setup 7 3 2 5 COM1 Setup 7 3 2 6 Exit with Save and Reset 8 3 2 7 Exit with Sav...

Страница 4: ...3 1 Device Search 20 A 3 2 Firmware 23 A 3 3 Configuration 24 A 3 4 About 26 Appendix B Specifications 28 B 1 Hardware Specifications 28 B 2 Software Specifications 29 B 3 Panel Layout and Connector...

Страница 5: ...Hardware Infrastructure Modbus Gateway supports the four most commonly used hardware communication interfaces RS232 RS485 RS422 and Ethernet The simple to use configuration software provided with Modb...

Страница 6: ...Data is transmitting on Ethernet for 100Mbps Blinking with Orange Data is transmitting on Ethernet for 10Mbps Table 1 LAN LED Message 2 1 2 COM Port LED Message Description Off No data is transmitting...

Страница 7: ...nnect ATC 3001 to Ethernet network Use a standard straight through Ethernet cable when one connect it to a hub switch one also can connect it to ones PC s Ethernet port via a cross over Ethernet cable...

Страница 8: ...admin Password Null leave it blank COM 1 9600 None 8 1 No flow control buffer disabled packet delimiter timer 2ms Modbus Type Listen port 502 SysName of SNMP name SysLocation of SNMP location SysCont...

Страница 9: ...HCP function By default the DHCP function on ATC 3001 is disabled one can use Device View software to search network information automatically by following steps Execute Device View Figure 3 1 Click o...

Страница 10: ...100 in Ms DOS command prompt window After telnet to ATC 3001 system prompts for a password the default password is left it blank Figure 3 4 Figure 3 4 Login to the system Note One can press the defaul...

Страница 11: ...2 2 IP Setup Select 2 from Input choice and enter 1 8 a f to Setup IP Figure 3 7 Figure 3 7 IP Setup 3 2 3 Gateway Setup Select 3 from Input choice and enter 1 8 a f to Setup Gateway Figure 3 8 Figure...

Страница 12: ...Reset Select 7 from Input choice and enter 1 8 a f to Exit with Save Please choose this option to save all the previous changes to EEPROM the device will restart automatically 3 2 7 Exit with Save an...

Страница 13: ...default empty password to 1111 Figure 3 12 change the password 2 If one want to change the password please type the old password in the Please input old password field type the new password in the Ple...

Страница 14: ...default password is null leave it blank 3 ATC 3001 s network link mode and COM ports settings can be configured in different web pages 4 Click Save Configuration to save settings 5 Click Restart butto...

Страница 15: ...in the Old Password field input the new password in the New Password and the Verified Password fields and then click on Save Configuration to update the password Note One can press the default key of...

Страница 16: ...ormation Enable SNMP by checking Enable fill in network identification information under SNMP field and click on the Save Configuration button to save the changes please notice that the setting will n...

Страница 17: ...to 0 Auto ATC 3001 will automatically chooses the optimal delimiter according to the baud rate 3 The COM Type Selection will show different port interface according to its selected port type 4 After...

Страница 18: ...Assign a New IP Address by ARP Command Use ARP command to assign a static IP address of ATC 3001 using its hardware MAC address The MAC address is printed on the rear side of device in the format of...

Страница 19: ...User Manual ATC 3001 1 port Modbus Gateway Copyright 2011 SHENZHEN ATC TECHNOLOGY CO LTD 15 Figure 3 21 Assigning a new IP address by ARP command...

Страница 20: ...k management tool from NetworkView Software Inc www networkview com It discovers all TCP IP nodes in a network using DNS SNMP and ports information and documents with printed maps and reports for futu...

Страница 21: ...isplay information about the device including IP Address Company SysLocation Max 15 characters SysName Max 9 characters and types etc Figure 4 4 Figure 4 4 NetworkView display device information Note...

Страница 22: ...Server IP address If the connection is established the Reply messages are displayed otherwise it will indicate Request timed out Figure 5 1 Figure 5 1 Standard TCP IP utility ping command 5 2 Use Dev...

Страница 23: ...User Manual ATC 3001 1 port Modbus Gateway Copyright 2011 SHENZHEN ATC TECHNOLOGY CO LTD 19 Figure 5 2 DeviceView configuration Utility...

Страница 24: ...Field Description IP conflict There are two devices with the same IP address in the network The device is using DHCP The device is being located You have logged into the device MAC conflict There are...

Страница 25: ...TC TECHNOLOGY CO LTD 21 Alternatively users can select by clicking the button on the toolbar as below Broadcast Search Once Broadcast Search is selected a box will pop up as below The user may type in...

Страница 26: ...ed an interface will pop up as below Here user may have two options Select an IP address to search or Search device in the range of IP address Search by MAC Address If Search by MAC Address is selecte...

Страница 27: ...all re search devices by using the current search way A 3 2 Firmware This function is applied to downloading a firmware into the selected device The user can enter the window for downloading by firstl...

Страница 28: ...them by selecting Apply for all selected devices have same model A 3 3 Configuration This function is for device configuration to set up parameters to import and to export the parameters and to set up...

Страница 29: ...to locate a device when its IP address is known but its position is unknown If a device is selected the device will appear to sing Users can locate the device by selecting the Configuration submenu Lo...

Страница 30: ...er setting directly through the submenu option Config by Browser and a Web browser is shown in the figure below Options The option is mainly applied to setting some common working rules of DeviceView...

Страница 31: ...User Manual ATC 3001 1 port Modbus Gateway Copyright 2011 SHENZHEN ATC TECHNOLOGY CO LTD 27...

Страница 32: ...ld 4 75V SerialPort Communication One RS 232 and one RS 485 RS 422 selectable RS 232 EIA RS 232C standard Full Duplex DB9 RS 485 2 4 wires Half Full duplex Terminal Block RS 422 4 wires Half Full dupl...

Страница 33: ...buffer size 16K bytes RS 232 or RS 485 RS 422 receiving buffer size 4K bytes RS 232 or RS 485 RS 422 transmitting buffer size 4K bytes B 3 Panel Layout and Connector Pin Assignments B 3 1 Pin Assignm...

Страница 34: ...5 Blue White Blue White Pin6 Orange Green Pin7 Brown White Brown White Pin8 Brown Brown One can choose either 568A or 568B definition If one want to make a crossover cable one should use 568A and 568B...

Страница 35: ...Data is transmitting on COM port Table 2 COM Port LED Message B 4 3 RUN LED Message Description LED on R1 are shorted to disable AP firmware running LED blinking rate 0 5Sec AP firmware is running nor...

Страница 36: ...DeviceView program to verify their availability 2 Prepare the download tool and press any key to edit its configuration file dapdl cfg dapdl cfg file can be found in the product CD 3 Edit the dapdl cf...

Страница 37: ...stem remains intact 2 If ATC 3001 does not receive any upgrading data within 30 seconds ATC 3001 will restart automatically and the system remains intact 3 After the upgrading process finishes ATC 300...

Страница 38: ...cur during the process Error Cause Message Comments Illegal Hex file format Hex File Text Error Hex File Check Sum Error Hex File Format Error Hex File End of Record Error ATC 3001 handshaking problem...

Страница 39: ...is used in the situation that one downloaded a wrong version of firmware that caused the system crashed To disable the current version of firmware and prevent it from executing please do the followin...

Страница 40: ...32 422 485 software selectable ATC 3001 Ports 1 port DB9 and 1 port TB6 Baud Rate 1200bps to 230Kbps Parity None Odd Even Mark Space Data Bits 7 or 8 Stop Bits 1 or 2 Data Packet Delimiter 0 to 30000...

Страница 41: ...HENZHEN ATC TECHNOLOGY CO LTD 37 Ordering Information ATC 3000 TCP IP to RS 232 RS 422 RS 485 converter ATC 3001 1 port Modbus Gateway Optional Accessories Power Adapter US315 12 US EU AC100 240V DC 9...

Отзывы: