Seite 30 von 39
Permanent water drain
In order not to empty the tank every time manually, you can install a permanent water drain.
This is especially recommended for:
Dehumidifier mode
as it generates a lot of water and the water tank fills up very
quickly.
If the water pump fails.
If you intend to use the device for a long period of time.
Proceed as follows to install the permanent water drain:
1. Completely empty the water tank before attaching a
matching water drain hose (16mmx1m) to the outlet.
2. Pull the plug of the condensation outlet for permanent
water drain and attach the water drain hose.
3. Put the other end of the hose into a catchment container
or drain making sure that the hose is not located higher
t
han the drain valve and that it’s not kinked.
4. Carefully re-attach the plug if you choose to remove the
permanent drain.
TASKS AT BEGINNING AND END OF SEASON
TASKS AT END OF SEASON
Carefully empty the condensed water tank into a suitable container as described in
the section on “emptying the water tank”.
Let the air conditioning unit run for 2 hours in the blower/fan mode until the device is
completely dry inside.
Switch the device off and pull the power plug.
Clean the filter and re-insert it after d
rying it (see section on “cleaning the air filter”).
Remove the air hose and the accessories and store them carefully.
Remove the batteries from the remote control.
Pack the device and store it at a cool and dry place.
CHECKS AT BEGINNING OF SEASON
Make sure the power supply cable and the outlet are fault free and that it is properly
grounded.
Make sure the plug is properly fitted to the condensation outlet and that the filters
have been inserted.
Observe the installation and safety instructions precisely.
Permanent Water drain