75
The malfunctions shown in the left-hand column below, labelled “Fault,” do not necessarily indicate functional
faults of the machine. It is therefore advisable to refer to “Checking” shown in the right-hand column before
calling for service.
Error message table
When the following error messages are displayed, press the
l
key and take a proper action according to the
table below.
Fault
Checking
The display won’t illuminate even when the mode switch
is turned to any other position than “ ”.
• Is power supplied to the electrical outlet?
• Is the power cord plug out or loosely connected to the
AC outlet?
(2)
The display shows symbols that do not make sense.
• Has the machine been initialized properly as shown in
“GETTING STARTED”?
(Note that initialization clears all the data and programmed
settings stored in memory.)
(1)
The display is illuminated, but the whole machine
refuses registrations.
• Is a clerk code assigned to the register?
• Is the mode switch set properly at the “REG” position?
(3)
No receipt is issued.
• Is the paper roll properly installed?
• Is there a paper jam?
• Is the receipt function in the “OFF” status?
• Is the print head release lever at the printing position?
(4)
No journal paper is taken up.
• Is the take-up spool installed on the bearing properly?
• Is there a paper jam?
(5)
Printing is unusual.
• Is the print head release lever at the printing position?
• Is the paper roll properly installed?
(6)
Before Calling for Service
9
Error message
Error status
Action
ENTRY ERROR
Registration error
Make a correct key entry.
MISOPERATION
Misoperation error
Make a correct key entry.
NO RECORD
Undefined code is entered.
Enter a correct code.
MEMORY FULL
Memory is full (in the AUTO key programming). Program the AUTO key within 25 steps.
SBTL COMPUL.
Compulsory depression of the
s
key for Press the
s
key and continue the operation.
direct finalization
TEND COMPUL.
Compulsory tendering
Make a tendering operation.
NOT ASSIGNED
No entry of a clerk code
Make a clerk code entry.
OVER LIMIT.
Overflow limitation error
Make a registration within a limit of entry.
INH. OPEN PR
The open price entry is inhibited.
Make a preset price entry.
INH. UNIT PR
The preset price entry is inhibited.
Make an open price entry.
NOT NON-TEND
The direct finalization is inhibited.
Make a tendering operation.
BUFFER FULL
Subtotal void is not allowed.
Finalize the transaction, and correct the wrong
entries in the
mode.
HEAD UP
Print head release lever is lifted up.
Move the lever toward the take-up spool (to the
printing position).
PAPER EMPTY
Receipt and/or journal paper roll is not
Install a receipt and/or journal paper.
installed or empty.
CLERK ERR.
CCD compulsory
Make CCD operation.
A301_5(En) 03.4.24 7:45 PM Page 75