32
VL-NZ50U/NZ100U
VL-NZ150U
4. COM-BIAS adjustment
Test point
LCD panel display surface
Address
VCR ADJ 33
Mode
VCR AV input
Procedure
1) Set the data of the address 582 to AF.
2) Set up the illuminance meter (TOPCON IM-3) on the LCD panel surface. (The outside light must not enter.)
3) Minimize the ripple of the output waveform of the illuminance meter.
4) Return the data of the address 582 to the initial value. (Initial value: 40)
Adjustment
Minimum
rating
Remark
Make this adjustment after 5-minute or longer aging.
Examples
• During LCD Panel replacement. • During IC705 replacement.
Response time : 0.6sec
5. White Balance adjustment
Test point
LCD panel display surface
Address
VCR ADJ 586, VCR ADJ 588
Mode
VCR AV input
Procedure
1) Set the data of the address 582 to AF.
2) Input the white 40% signal to the standard monitor, and adjust it to become equal to that of the screen.
3) Return the data of the address 582 to the initial value. (Initial value: 40)
Adjustment
Standard monitor
rating
Remark
Make this adjustment after 5-minute or longer aging.
Examples
• During LCD monitor replacement. LCD Panel • During IC4401, IC705 replacement.
Содержание ViewCam VL-NZ100U
Страница 80: ...108 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 VL NZ50U NZ100U VL NZ150U 14 29 OPERATION SCHEMATIC DIAGRAM ...
Страница 82: ...110 A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 VL NZ50U NZ100U VL NZ150U 14 31 CCD SCHEMATIC DIAGRAM ...
Страница 83: ...111 10 11 12 13 14 15 16 17 18 19 VL NZ50U NZ100U VL NZ150U M E M O ...
Страница 94: ...126 VL NZ50U NZ100U VL NZ150U A B C D E F G H I J 1 2 3 4 5 6 7 8 9 10 SIDE A CARD PWB SW1501 1 SC1501 ...