CHAPTER 8.
POLE DISPLAY UNIT : UP-P16DP
1) Remove the rear cover.
2) Connect the display cable
to the POLE connector
.
3) Fix the earth wire
to the main chassis
with a screw
.
4) Install the core
to the display cable
and earth wire
.
Secure the core
with two wire bands.
NOTE: Install the ferrite core in a position less than 50mm from the
cabinet.
CHAPTER 9. RS-232 I/F :ER-A5RS
1. ER-A5RS CHANNEL SETTING
The ER-A5RS ports can be set to channel 1-7 and invalid (inhibit)
with SW1 on the PWB.
SW1 setting contents
SW1 1~3 are used for channel setting of RS-232 connector 1
(RSCN1).
SW1 4~6 are used for channel setting of RS-232 connector 2
(RSCN2).
SW1
RSCN1
setting
SW1
RSCN2
setting
3
2
1
6
5
4
0
0
0
RS-232 invalid
0
0
0
RS-232 invalid
0
0
1
Channel 1
0
0
1
Channel 1
0
1
0
Channel 2
0
1
0
Channel 2
0
1
1
Channel 3
0
1
1
Channel 3
1
0
0
Channel 4
1
0
0
Channel 4
1
0
1
Channel 5
1
0
1
Channel 5
1
1
0
Channel 6
1
1
0
Channel 6
1
1
1
Channel 7
1
1
1
Channel 7
Note
1) If RSCN1 port and RSCN2 port of the ER-A5RS are set to the
same channel, RSCN2 port becomes invalid and only RSCN1 is
valid.
2) If RSCN of the ER-A5IN and the ER-A5RS connector are set to
the same channel, the buses compete and the operation cannot
be assured. In addition, it may break the hardware. Never set the
two to the same channel. Be sure to set them to different channels
or to set invalid.
2
1
3
5
4
6
Earth wire
Cabinet
MCR cable
Wire band
Wire band
Core
Within 50mm
OPTCN1
RSCN1
RSCN2
(1)
(0)
SW1
6
5
4
3
2
1
6
5
4
3
2
1
CN2
CN1
1
0
O
F
F