AX1500J(S)
7 – 7
8. Remove the one (1) screw holding the filter cover to the bottom
plate.
9. Straighten the tab of the bottom plate holding the filter cover to the
bottom plate.
10.Remove the filter cover from the bottom plate.
11.Remove the one (1) nut holding the earth wire of the power supply
cord to the bottom plate.
12.Disconnect the wire leads of the power supply cord from the noise
filter unit and the wire harness.
13.Remove the power supply cord from the square hole of the bottom
plate.
2. Installation
1. Insert the moulding cord stopper of the power supply cord into the
square hole of the bottom plate, referring to the figure.
2. After inserting the moulding cord stopper, slide it to the right side.
3. Install the earth wire lead of the power supply cord to the bottom
plate with the one (1) nut. And tight the nut.
4. Connect the wire leads of the power supply cord to the noise filter
unit correctly, referring to “CIRCUIT DIAGRAMS”.
5. Reinstall the filter cover to the bottom plate with the one (1) screw.
6. Hold the filter cover to the bottom plate by bending the tab of the
bottom plate.
7. Reinstall the bottom plate assembly to the oven.
8. Reconnect all leads removed from components during testing.
9. Reinstall the outer case and the back plate assembly.
10.Reconnect the power supply cord after the outer case and the back
plate assembly are installed.
11.Run the oven and check all function.
1
2
Power supply cord
Bottom plate
Square hole
Moulding cord stopper